Read Harman Kardon AVR 505 (serv.man13) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 23 of 37 -
Order
No.
11151
14.6.1
Permanently connected equipment
provided with an all-pole mains
switch unless 5.4.2 is met
provided with an all-pole mains
switch unless 5.4.2 is met
Apparatus is not permanently connected
N
14.6.2
Manually operated mechanical
switch (MOMS), required where
power consumption > 15 W and/or
peak voltage > 4 kV
switch (MOMS), required where
power consumption > 15 W and/or
peak voltage > 4 kV
Yes. MOMS required. See table above.
P
Switch readily accessible and not in
mains cord
mains cord
Switch located on the front and readily accessible
P
Exception for automatic switching
N
Exception for continuous operation
N
14.6.3
Manually operated mechanical
switch (MOMS): Switch indication /
On position clearly discernible
switch (MOMS): Switch indication /
On position clearly discernible
The display is illuminated.
P
Indication by marking meets Cl. 5
Yes
P
Indication of the OFF position
Off-position marked with “OFF”
P
14.6.4
Manually operated mechanical
switch (MOMS) fitted. Is there a
Stand-by mode
switch (MOMS) fitted. Is there a
Stand-by mode
Yes
P
Stand-by mode clearly discernible
LED indication
P
Exception for low Stand-by current
< 0,7 mA (peak)
< 0,7 mA (peak)
N
14.6.5
Components bridging contacts of
mains switches comply with 14.1 a)
or 14.2.2
mains switches comply with 14.1 a)
or 14.2.2
Yes,
Switch for C853, and relay for C904.
See also clause 14.2.
Switch for C853, and relay for C904.
See also clause 14.2.
P
14.6.6.a.
Manually operated mechanical
switches (MOMS) separately
approved to IEC 61 058-1
switches (MOMS) separately
approved to IEC 61 058-1
Yes.
- Mains switch, certified by VDE,
- Mains relay, certified by SEMKO.
- Mains switch, certified by VDE,
- Mains relay, certified by SEMKO.
P
14.6.6.b.
Manually operated mechanical
switch (MOMS) tested as part of the
equipment complies with 14.6.7,
14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
switch (MOMS) tested as part of the
equipment complies with 14.6.7,
14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
N
Flame test for mains switches
N
14.6.7 Endurance
test
N
14.6.8
Temperature rise in mains switch
N
14.6.9
Dielectric strength test
N
14.6.10
Surge current for mains switches
also controlling mains socket-outlets
also controlling mains socket-outlets
Measured mains relay / switch surge current : 36A
Socket-outlet through current (50W)
Socket-outlet through current (50W)
: 20A
Mains switch / relay controlling total current
: 56A
The measured surge current value is less than rated surge
current rating of the mains relay and switch. OK.
Ref. clause 7.
P