DPF-D1010, DPF-D1020, DPF-D710, DPF-D720, DPF-D810, DPF-D820 - Sony Other Service Manuals Service Manual (repair manual). Page 10

Read Sony DPF-D1010 / DPF-D1020 / DPF-D710 / DPF-D720 / DPF-D810 / DPF-D820 Service Manual online

DPF-D710/D720/D810/D820/D1010/D1020
– 10 –
Set the destination when the MAIN PWB Assy SERVICE was replaced.
The following procedures are used in DPF-D720 model.
Conduct the same adjustment for the other models.
2-1.  HOW  TO  CHANGE  THE  DESTINATION
Procedure
1.  Plug the AC adapter attached to the set into the DC IN 5V(DPF-
D710/D720/D810/D820)  or  12V(DPF-D1010/D1020)  terminal 
on the rear panel of the set and insert the power cord into the socket. 
Press  the  1  (on/standby)  button  to  turn  off  the  power  once.
(The power switch LED on the set changes from green to red.)
2.  With the [VIEW MODE] button and [MENU] button pressed, turn 
on  the  1  (on/standby)  button,  and  when  the  default  setting
screen (Fig. 2-1-1) appears, release the [VIEW MODE] button and 
[MENU] button.
3.  Check  that  the  model  name  displayed  on  the  side  of  “Model” 
name meets the following: 
D710 
DPF-D710
D720 
DPF-D720
D810 
DPF-D810
D820 
DPF-D820
D1010 
DPF-D1010
D1020 
DPF-D1020
Note:Using [B] [b] buttons, move a yellow frame to the model    
 
name to be set.
4.  Red characters of “Destination” show default setting of this set. 
(Fig.  2-1-1  shows  that  the  destination  has  been  set  to  J1) 
Using  [V]  [v]  [B]  [b]  buttons,  move  a  yellow  frame  to  the
destination to be set. (Fig. 2-1-1 shows that U2 has been selected as 
destination.)
5.  Press the [ENTER] button, and the characters will change to red, 
indicating that the selected destination was set. (Fig. 2-1-2) 
2-2.  CONFIRMATION OF DESTINATION
6.   With  a  yellow  frame  moved  to  “Restore  all  setting”,  press  the 
[ENTER] button. (Fig. 2-1-3)
7.   The screen becomes green and the setting is complete. (Fig. 2-1-4)
8.  With green screen displayed, unplug the AC adapter from the DC 
IN 5V (DPF-D710/D720/D810/D820) or 12V (DPF-D1010/D1020)  
terminal.
9.  Plug the AC adapter into the DC IN 5V (DPF-D710/D720/D810/
D820)  or  12V  (DPF-D1010/D1020)  terminal  and  turn  on  the 
power.
10.  Press the [MENU] button to display the Settings menu, and select 
“Initialize”, to execute. (Fig. 2-1-5)
12.  Select “Yes” for the dialog message “All settings will be returned 
to factory default.” to execute. (Fig. 2-1-7)
1.  Press the [MENU] button to display the menu, and if the language 
you selected is set, the setting has been completed.
– ENGLISH –
13.  Select “OK” for the dialog message “Completed” to finish all the 
initialize settings. (Fig. 2-1-8)
Fig. 2-1-1
Model:
CED
CEP
CEU
E37
E33
E32
JE3
KR2
CN9
TW6
HK4
Restore all setting
XXXXXXXXX XXXXXXXXX - X
U2
CA2
CEK
Destination:
AR2
BR4
E35
J1
AU3
D720
Fig. 2-1-2
Model:
CED
CEP
CEU
E37
E33
E32
JE3
KR2
CN9
TW6
HK4
Restore all setting
XXXXXXXXX XXXXXXXXX - X
U2
CA2
CEK
Destination:
AR2
BR4
E35
J1
AU3
D720
Fig. 2-1-3
Model:
CED
CEP
CEU
E37
E33
E32
JE3
KR2
CN9
TW6
HK4
Restore all setting
XXXXXXXXX XXXXXXXXX - X
U2
CA2
CEK
Destination:
AR2
BR4
E35
J1
AU3
D720
Fig. 2-1-4
Fig. 2-1-5
Settings
Slideshow Settings
Auto Power ON/OFF
Date/time Settings
General Settings
System Information
   
Language Setting
Initialize
ENTER
BACK
Select
End
/
A
Slideshow Sound Setting
Fig. 2-1-
6
ENTER
BACK
Select
Return
/
Initialize
Format internal memory
Initialize settings
All settings will be
returned to factory default.
Yes
Fig. 2-1-
7
No
Completed
OK
Fig. 2-1-
8
11.  Select “Initialize settings” of “Initialize” to execute. (Fig. 2-1-6)