Read Sony HDR-PJ800 / HDR-PJ810 / HDR-PJ810E / HDR-PJ820 / HDR-PJ820E (serv.man2) Service Manual online
1-3
HDR-PJ800/PJ810/PJ810E/PJ820/PJ820E_L2
– ENGLISH –
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
4
1
0
0
Wi-Fi Module Hardware Error
Check that connection between CN4902 on the VC-1022 board and
CN2301 on the WF-1004 board by FP-2181 flexible board.
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Inspect the lens block zoom signal (pin wg, wh, rj, rk of CN6801 on
the LD-1014 board when zooming is performed when the zoom lever
is operated, and the zoom motor drive circuit (IC6800 on the LD-1014
board) when zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of the focus
lens and the abnormalities in initialization of
the zoom lens occurred simultaneously.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
E
6
1
3
0
Reset position detection error on the stepper
iris initializing
Turn the power on to open lens barrier. Disconnect the battery or power
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens drive
block (pin ef, eg, ej, ek, r;, ra of CN6801 on the LD-1014 board).
If iris blades work normally, confirm that they are closing completely
and confirm following item.
・ Case of the iris blades do not close normally Replace the lens block).
・ Case of “E: 61: 30” is appeared and iris blades closed completely.
・ Case of the iris blades do not close normally Replace the lens block).
・ Case of “E: 61: 30” is appeared and iris blades closed completely.
Confirm that communication with lens block is normal.
・ Case of LCD is not displayed normally Check that connection be-
・ Case of LCD is not displayed normally Check that connection be-
tween CN1001 on CM-1007 board and CN4004 on VC-1022 board
by LF-2063 flexible board.
・ Case of LCD is displayed normally Replace the lens block.
E
6
1
3
1
Error in detection of the Reset Position at the
time of Stepper IR Filter initialization.
Check that connection between CN6801 on the LD-1014 board and
the lens block by LF-2026 flexible board.
E
6
2
0
0
Handshake correction function does not work
well. (With PITCH angular velocity sensor
output stopped.)
Inspect PITCH angular velocity sensors (SE7701 on the LD-1014
board) peripheral circuits.
E
6
2
0
1
Handshake correction function does not work
well. (With YAW angular velocity sensor
output stopped.)
Inspect YAW angular velocity sensors (SE7701 on the LD-1014 board)
peripheral circuits.
E
6
2
0
2
Abnormality of IC for steadyshot.
Refer to “1-6-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred”.
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
Inspect the steadyshot circuit (IC6800 on the LD-1014 board).
E
6
2
0
4
Image vibration correction during handshake
function does not work.
Inspect the image vibration angular velocity sensors (SE7711 on the
OC-1003 board) peripheral circuits.
E
6
2
1
0
Shift lens initializing failure.
Replacement of lens block (Note 3).
If an error occurs again, replace the LD-1014 board.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to “1-6-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred”.
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to “1-6-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred”.
E
6
2
2
0
Abnormality of thermistor.
Refer to “1-6-4. E : 62 : 20 (Abnormality of Thermistor) Occurred”.
E
6
2
3
0
Abnormal CPU
Turn power off and turn power on again.
E
9
1
0
1
Abnormality when flash is being charged.
Check or replace the LED Flash/Video light or charging capacitor.
E
9
1
0
2
Abnormality of LED Video light.
Check or replace the LED Flash/Video light or charging capacitor.
E
9
1
0
3
Abnormality of LED Video light Tempera-
ture detection.
Check or replace the LED Flash/Video light or charging capacitor.
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
9
2
0
1
Battery current value goes over the max
discharge current
Check the remaining battery power because this symptom maybe
depended on the remaining battery level, and confirm whether or
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each
output of DC/DC converter (IC5100 on the VC-1022 board) with
connected the DC JACK (J901) on the VC-1022 board.
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing the flash mem-
ory
PJ810/PJ810E:
Inspect the flash memory (IC8101 on the MM-102 board).
PJ800/PJ820/PJ820E:
Inspect the flash memory (IC8101, IC8201 on the MM-102 board).
E
9
4
0
1
Internal flash memory fault
PJ810/PJ810E:
Inspect the flash memory (IC8101 on the MM-102 board).
PJ800/PJ820/PJ820E:
Inspect the flash memory (IC8101, IC8201 on the MM-102 board).
E
9
4
0
2
BGM data error
Check the CPU (IC6000 on the VC-1022 board).
E
9
5
0
0
GPS hardware error
Turn power off and turn power on again.
E
9
5
0
1
Acceleration sensor HW error
Check that connection between CN4901 on the VC-1022 board and
CN4501 on the PD-1027 board by FP-2180 flexible board.
CN4501 on the PD-1027 board by FP-2180 flexible board.
E
9
6
0
0
Map area mount error
Turn power off and turn power on again.
E
9
7
0
0
Projector hardware error
Turn power off and turn power on again.
Note: Functions of codes with * mark are not provided in this unit.
1-6. METHOD OF COPING WITH SHIFT LENS ERROR
R1401
IC6800
C6814 C6815
C6816 C6817
LD-1014 BOARD (SIDE A)
Fig. 1
Measurement points on the LD-1014 board
*
*
Click on the first or last page to see other HDR-PJ800 / HDR-PJ810 / HDR-PJ810E / HDR-PJ820 / HDR-PJ820E (serv.man2) service manuals if exist.