SECTION  3
TEST  MODE
1.  PANEL  TEST 
Procedure:
1.  The [POWER] switch is set [ON] to turn the main power on.
2.  While pressing the [S-AIR MODE] and [SYSTEM MENU] 
buttons, press the [PAIRING] button.
3.  Then all segments of fl uorescent indicator tube are turned on 
and all LEDs are lighted.
4.  Press the [SYSTEM MENU] button, the model name is dis-
played on the fl uorescent indicator tube.
5.  Each time [SYSTEM MENU] button is pressed, the display 
changes starting from model name, destination, MC, SYS, UI, 
ST and AR version this order, and returns to the model name 
display.
6.  Press the [ILLUMINATION] button, the version is displayed 
changes to last updated date displayed.
7.  Press the [S-AIR MODE] button, the messages “K 0” is 
displayed on the fl uorescent indicator tube. All buttons are 
pressed, display becomes “K 7”.
8.  To release from this mode, while pressing the [S-AIR MODE] 
and [SYSTEM MENU] buttons, press the [PAIRING] button.
2.  FACTORY  PRESET
Procedure:
1.  The [POWER] switch is set [ON] to turn the main power on.
2.  While pressing the [S-AIR MODE] and [TUNING/SELECT 
–] buttons, press the [PAIRING] button.
3.  The messages “TUNER” appears and initialization is per-
formed, and the messages “FM 87.50” appears.
3.  S-AIR  TEST
3-1.  S-AIR test mode
Setting method:
1.  The [POWER] switch is set [ON] to turn the main power on.
2.  While pressing the [S-AIR MODE] and [TUNING/SELECT 
+] buttons, press the [PAIRING] button.
3.  Entered the S-AIR test mode.
4.  It returns to the S-AIR test mode each item when [SYSTEM 
MENU] button is pressed after it enters each item.
5.  To release from this mode, while pressing the [S-AIR MODE] 
and [TUNING/SELECT +] buttons, press the [PAIRING] but-
ton.
3-1-1. Power setting
This mode is setting of radio wave output of EZW-RT10A.
Procedure:
1.  Enter the S-AIR test mode.
2.  Press the [TUNING/SELECT +]/[TUNING/SELECT –] but-
tons to select “POWER”.
3.  Press the [ENTER] button the messages “000 SET” is dis-
played on the fl uorescent indicator tube.
4.  Press the [TUNING/SELECT +]/[TUNING/SELECT –] but-
tons to select the radio wave output. (OFF or 000 to 063)
5.  Press the [ENTER] button, return to S-AIR test mode each 
item.
3-1-2.  RF CH check
This mode is RF CH used is confi rmed.
Procedure:
1.  Enter the S-AIR test mode.
2.  Press the [TUNING/SELECT +]/[TUNING/SELECT –] but-
tons to select “CHK RFCH”.
3.  Press the [ENTER] button the messages “*** CH#” is dis-
played on the fl uorescent indicator tube.
 
***: ON or OFF
 
#: CH number used
4.  Press the [ENTER] button, return to S-AIR test mode each 
item.
3-1-3.  ENC key change
This mode is setting of code key on/off change of EZW-RT10A.
Procedure:
1.  Enter the S-AIR test mode.
2.  Press the [TUNING/SELECT +]/[TUNING/SELECT –] but-
tons to select “ENC KEY”.
3.  Press the [ENTER] button the messages “ON” or “OFF” is 
displayed on the fl uorescent indicator tube.
4.  Press the [TUNING/SELECT +]/[TUNING/SELECT –] but-
tons to select the “ON” or “OFF”.
5.  Press the [ENTER] button, return to S-AIR test mode menu.
3-1-4. Version check
This mode is S-AIR version of the set connected with AIR-SA17Ti 
is confi rmed.
Procedure:
1.  Enter the S-AIR test mode.
2.  Press the [TUNING/SELECT +]/[TUNING/SELECT –] but-
tons to select “VER. CHEC”.
3.  Press the [ENTER] button, S-AIR version of the set connected 
with AIR-SA17Ti is displayed on the fl uorescent indicator.
4.  Press the [TUNING/SELECT +]/[TUNING/SELECT –] but-
tons, change the version and date displayed.
5.  Press the [ENTER] button, return to S-AIR test mode each 
item.
3-1-5.  DARR setting check
This mode is setting of EZW-RT10A is confi rmed.
Procedure:
1.  Enter the S-AIR test mode.
2.  Press the [TUNING/SELECT +]/[TUNING/SELECT –] but-
tons to select “DARR”.
3.  Press the [ENTER] button, main unit connect code is displayed 
on the fl uorescent indicator.
4.  Press the [TUNING/SELECT +]/[TUNING/SELECT –] but-
tons, change sub unit connection number, sub unit connect 
code and sub unit address this order, and returns to the main 
unit connect code display.
 
CO ****: main unit connect code
 
MUCNT **: sub unit connectoin number
 
MUCO****: sub unit connect code
 
MUADR **: sub unit address
 
NAMG ***: NAMG setting value
5.  Press the [ENTER] button, return to S-AIR test mode each 
item.