Read Sharp 32JF-74H (serv.man19) Service Manual online
1
32JF-74H
MODEL
32JF-74H
PAL I SYSTEM COLOUR TELEVISION
SE
00
32JF74H00
SERVICE MANUAL
Issued: 1
st
July 2002
GA-20
CHASSIS
In the interests of user safety (required by safety
regulations in some countries) the set should restored
to its original condition and only parts identical to
those specified should be used.
regulations in some countries) the set should restored
to its original condition and only parts identical to
those specified should be used.
CONTENTS
ELECTRICAL SPECIFICATIONS ................... 3
IMPORTANT SERVICING NOTES ................. 4
CONTROLS & TERMINALS ........................... 5
ADJUSTMENT PROCEDURES ...................... 7
POSTCODE RESET ...................................... 11
LED FLASHING CODES ............................... 12
PRINTED WIRING BOARDS ........................ 13
IMPORTANT SERVICING NOTES ................. 4
CONTROLS & TERMINALS ........................... 5
ADJUSTMENT PROCEDURES ...................... 7
POSTCODE RESET ...................................... 11
LED FLASHING CODES ............................... 12
PRINTED WIRING BOARDS ........................ 13
CHASSIS LAYOUT ......................................... 20
ICs ADDITIONAL INFORMATION .................. 22
SCHEMATIC DIAGRAMS ............................... 37
TROUBLESHOOTING TABLES ..................... 51
PARTS LISTING ............................................. 54
SOURCE OF DOCUMENTATION .................. 62
PACKING OF THE SET & ACCESSORIES ... 63
ICs ADDITIONAL INFORMATION .................. 22
SCHEMATIC DIAGRAMS ............................... 37
TROUBLESHOOTING TABLES ..................... 51
PARTS LISTING ............................................. 54
SOURCE OF DOCUMENTATION .................. 62
PACKING OF THE SET & ACCESSORIES ... 63
SHARP CORPORATION
8
2
32JF-74H
Use this page to keep any special servicing information as Technical Report (Bulletin), Technical Information, etc.
If only part number changes are required, just change part number directly the part number in the Parts Listing Section.
If you need more information, please refer to the Technical Report (Bulletin).
If only part number changes are required, just change part number directly the part number in the Parts Listing Section.
If you need more information, please refer to the Technical Report (Bulletin).
SERVICE MANUAL UPDATE LOG SHEET
Part No.
Technical Report No.
Technical Bulletin No.
Technical Bulletin No.
Cause / Solution
Page No.
Application
Data /Serial No.
Data /Serial No.
3
32JF-74H
ELECTRICAL SPECIFICATIONS
•Focus ....................... High Bi-Potential Electrostatic
•Sweep Deflection ..................................... Magnetic
•Picture Intermediate frequency................... 38.9MHz
•Sound Carrier Trap................................... 32.9MHz
•Adjacent Sound Carrier Trap ................... 40.9MHz
•Adjacent Picture Carrier Trap.................. 30.9MHz
.
•Aerial Input Impedance
VHF/UHF ...................... 75 ohm Unbalanced
•Tuning Ranges........... 45.75 MHz thru 855.25 MHz
VHF: IR A - J / S1 - S41 CH (Hiperband)
UHF: I21 - I69 CH
UHF: I21 - I69 CH
•White Level
Set brightness control to get total picture tube cathode current of 600
µA under no signal condition.
Maximum necessary correction of each picture tube cathode current to get 8900 degrees
K-20 MPCD
screen temperature should not exceed 15% of its original value.
X=0.290 ± 0.015 Y=0.284 ± 0.015
WARNING
The chassis in this receiver is partially hot. Use an isolation transformer between the line cord plug
and power receptacle, when servicing this chassis.
To prevent electric shock, do not remove cover. No user-serviceable parts inside. Refer servicing to
qualified service personnel.
and power receptacle, when servicing this chassis.
To prevent electric shock, do not remove cover. No user-serviceable parts inside. Refer servicing to
qualified service personnel.
Specifications are subject to change without prior notice.
•Power Input .................... 220V-240 Volts AC 50Hz
•Power Consumption
Normal Operation (Method IEC60107) ............ 85W
Stand-by Operation ............................................ 3W
Stand-by Operation ............................................ 3W
•Audio Power Output Rating (MPO) / Impedance
Internal Left Speaker ................................. 10W, 7
Ω
Internal Right Speaker .............................. 10W, 7
Ω
•Speakers
Left / Right ................................................. 12 x 6cm
•Convergence (Maximum Misconvergence)
Static (Centre) between any two colours ... 0.08 cm
Dynamic after static equals zero
Dynamic after static equals zero
Within 10cm (4”) circle ....................... 0.12cm
10-25cm (4-10” ) circle ...................... 0.20 cm
Everywhere else ................................ 0.28 cm
10-25cm (4-10” ) circle ...................... 0.20 cm
Everywhere else ................................ 0.28 cm
4
32JF-74H
IMPORTANT SERVICING NOTES
Only qualified service personnel are allowed to carry out maintenance and repair of this receiver.
Servicing of High Voltage System and CRT
It is important that the static charge is removed from the high voltage system when carrying out work on the
receiver. This can be achieved by connecting a 10K resistor (with a suitably insulated lead) from the CRT
cavity connector to the CRT ground tag. This must be carried out with the AC supply disconnected from the
receiver.
receiver. This can be achieved by connecting a 10K resistor (with a suitably insulated lead) from the CRT
cavity connector to the CRT ground tag. This must be carried out with the AC supply disconnected from the
receiver.
Note the following:
•
The CRT in this receiver employs Integral Implosion Protection.
• If the CRT has to be changed it MUST be replaced with the correct type for continued safe working.
• DO NOT lift the CRT by its neck.
• When handing the CRT, ensure that shatterproof goggles are worn.
• Ensure that the CRT is discharge before handling.
X-Ray
This receiver is designed to keep any x-ray emission to an absolute minimum. Some fault conditions and
servicing procedures may produce potentially hazardous x-ray radiation levels. This is a problem when in
close proximity to the receiver for long periods of time. To reduce any risks associated with this, please
observe the following precautions:
servicing procedures may produce potentially hazardous x-ray radiation levels. This is a problem when in
close proximity to the receiver for long periods of time. To reduce any risks associated with this, please
observe the following precautions:
1. When undertaking any servicing on this chassis, DO NOT increase the EHT to more than 33.0 KV, (at a
instantaneous beam current of 1500
µA
)
.
2. Ensure that during normal operation the EHT does not exceed 30.5 KV±1.5KV (at a beam current of
1800
µA). This level has been preset in the factory. Always check that this level has not been exceeded
after carrying out any repair on the receiver.
3. DO NOT replace the CRT with any other type than that specified in the parts listing as this may cause
excessive x-ray radiation.
Before returning the receiver to the customer
In addition to the above checks, the following should also be carried out before returning the receiver to the
customer.
customer.
1. Inspect all the leads to ensure that they are dressed correctly and that they are not obstructed or pinched
by any other parts.
2. Ensure that all protective devices are in good condition. These will include nonmetallic control knobs,
insulating fish papers, cabinets backs, compartment covers or shields, mechanical insulators, etc.