Main unit cassette heater installation procedures
Quantity
Part name
Part code
EX100
EX200
T heater cover
PCOVP1654FCZ2
1
1
Heater mount plate
LPLTM6089FCZZ
1
1
RHETP0141FCPZ
1
0
Cassette dehumidifier heater
RHETP0143FCPZ
0
1
M3x8S tight
XHBS730P08000
3
3
High temperature warning label in 5 languages
TCAUH1035FCZZ
1
1
Note: If the electrical component kit has not been installed, install the kit first.
Procedures
1.Place the dehumidifier heater onto the heater mount plate, and tighten with M3x8S tight (x1).
*Nail of the heater mount plate must be opposite in direction to the harness.
2.Place the heater mount plate in step 1 onto the T heater cover and tighten it with M3x8S tight (x2).
3.Hold down a clamp (one clamp).
4.Affix the 5-language high temperature warning label onto the T heater cover, fitting to the reference line.