Read Sharp AR-505 (serv.man10) Service Manual online
(6) Transfer/separation charger
(The illustrations are the same as those of the AR-335.)
∗
When replacing the charger wire:
•
Be careful not to twist or bend the wire.
•
Stretch the wire so that the tension spring length is as shown
above.
above.
•
Securely put the charger wire in the groove.
1
1
2
1
10 0.5mm
1
2
3
No.
Name
Work item
Cycle
Remark
AR-250/280/281/
285/286/335/336
285/286/335/336
AR-405
AR-501/
505
1
Charger wire (TC/AC)
Replace
80 K
90 K
125K
2
Charger case (MC/TC/AC)
Clean
80 K
90 K
125K
3
Separation lamp
Clean
—
—
125K
8 – 9
8/6/1999
Click on the first or last page to see other AR-505 (serv.man10) service manuals if exist.