AL-1000, AL-1010 (serv.man12). AL1000 Simulation, Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 10

Read Sharp AL-1000 / AL-1010 (serv.man12) Service Manual online

Main code
Main code
Contents
26
20
Rear edge void setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of rear edge void setting is displayed.
2. Enter the code number of rear edge void setting and press the START key, and the setting will be changed.
Code number
Rear edge void setting
0
Rear edge void allowed
1
Rear edge void not allowed
30
CE mark application control ON/OFF setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of CE mark application is displayed.
2. Enter the code number of CE mark application and press the START key, and the setting will be changed.
Code number
CE mark application setting
0
CE mark application control OFF
1
CE mark application control ON
38
Drum life over stop cancel
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed. 
2. Enter the code number and press the START key, and the setting will be changed.
Code number
Setting
0
Stop at drum life over
1
Stop cancel at drum life over
39
Memory capacity setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed. 
2. Enter the code number and press the START key, and the setting will be changed.
Code number
Setting
0
No  memory
1
4Mbyte
2
6Mbyte
40
Polygon motor OFF time setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed. 
2. Enter the code number and press the START key, and the setting will be changed.
Code number
Setting
0
0  sec
1
30 sec
2
60 sec
3
90 sec
42
Transfer ON timing control (Setting the time to transfer ON)
(Operation / Procedure)
1.When this simulation is executed, the currently set code number is displayed.
2.Enter the code number and press the START key, and the setting will be changed. (For any number different
from the following ones, the default time is automatically set.)
Code number
Setting
0
Default (330 msec)
1
-40msec
2
-30msec
3
-20msec
4
-10msec
5
Default (330 msec)
6
+10msec
7
+20msec
8
+30msec
9
+40msec
AL-1000/1010
10-6
Page of 15
Display