LL-191A - Sharp Monitor Service Manual (repair manual). Page 10

Read Sharp LL-191A Service Manual online

LL-191A-W/B
CONNECTION, ADJUSTMENT, OPERATION, AND FUNCTIONS
2 – 7
3.
Select the check [Clerk Security File] botton at the lower right area
of the window.
The following window is displayed
4.
Set the [MTV Type] value for MTV312M64.
5.
Push the [Load MCU file] button and chose the firemware to write in.
(Published separately is the firmware.)
Since the following screen is displayed, click [O.K.].
6. Hold down the [MODE] + [
1
] + [
3
] buttons and press the
[POWER] button.
7. The ISP window is displayed. Set it for "GO" or "ON" using
the [
1
] button.
8. Click [RUN] on the window screen on PC.
Begun writeing.
9. When writing the firmware ends, the following window is displayed.
Caution: If the following window is displayed
it is supposed that:
1.
When an error will occur if [RUN] is pushed, additional connec-
tion of a writing board, PC, and a monitor is checked.
2.
Lower the gauge of CPU speed on the side of the RUN button
in the window from High to about five when the error is dis-
played after writing ends.
10. If the LEDs (green and orange) come on, press the [POWER] but-
ton to turn them off.
11. [Execute All] reset. 
Hold down the [MENU] + [MODE] buttons and press the [POWER] button.
12. Check the version
Hold down the [MENU] + [
3
] button and press the [POWER] button.
Either of the following notifications appears. Check the model
name, version, date and checksum.
13. Turn off the AC power supply using the AC power supply switch.
ISP SLAVE Add.
= 7c
SlebeB Add.
= 4c
Command 1
= 77
inputs, and click [OK]
MODE NAME
VERSION
DATE
CHECKSUM
V-sync
H-sync
: 191AE
: 1.02 
: 01/07/2004
: 21BA
: 60H
: 48kHz
Page of 31