XE-A212 (serv.man2). Program Manual - Sharp ECR Service Manual (repair manual). Page 4

Read Sharp XE-A212 (serv.man2) Service Manual online

XE-A212
PROGRAM MODE
2 – 2
2. USER PROGRAMMING
1) PRICE PROGRAMMING FOR DEPT.& (-) KEYS
If a price is set for a department which amount entry type is “INHIBIT” or
“OPEN”, its amount entry type is set as below automatically.
MRS = 0
2) DEPT FUNCTION PROGRAMMING
2  Programming report 2
Job code
A to H from the left
Training clerk specification
Training mode text
Language selection
EJ memory type
* Job code #65, 70, 71, 72, 
76, 77 and 95 are fixed 
settings, for which you 
cannot change the 
settings.
3  Printer density programming report
Entered value
Printer density
Printing density
example
4  Department programming report
Dept. unit price 
w/sign
Dept. function
Minus department
Tax status
Dept. code
Dept. text
5  PLU programming report
PLU code
PLU text
Mode parameter
Unit price
Range
Associated
dept. code
YY: Department Code (01-50)
XXXXXX: Unit price (Max. 6 digits)
“PRESET”
”INHIBIT”
“OPEN & PRESET”
1
 ”OPEN”
YY: Department code (01-50)
A: Taxable 4
A
No
0
Yes
1
B: Taxable 3
B
No
0
Yes
1
C: Taxable 2
C
No
0
Yes
1
D: Taxable 1
D
No
0
Yes
1
E: REGISTRATION TYPE
E
NORMAL
0
SICS
1
F: SIGN
F
+
0
-
1
G: LIMITATION DIGITS = 0 to 8
0 : OPEN PRICE REGISTRATION INHIBIT.
XXXXXX
YY
XXXXXX
0
0
TL
DPTn
DEPT#
ST
(-)
ABCDEFGH
ABCDEFGH
YY
0
0
TL
DPTn
DEPT#
Page of 24
Display