ER-A220 (serv.man2) - Sharp ECR Service Manual (repair manual). Page 3

Read Sharp ER-A220 (serv.man2) Service Manual online

[Functions]
Function for each key position
SRV ’ :
System reset
SRV :
Service mode (SRV/PGM programming)
PGM :
Allows programming of an item that is not changed fre-
quently, in addition to the PGM mode programming.
OP, X/Z :
Allows X or Z operation by cashiers.
REG :
Allows registrations.
MGR :
Allows the operations, by authorized person such as a
manager (e.g. correction after transaction finished or
cancellation of entry limits), which are not permitted to
ordinary cashiers.
X1/Z1 :
Allows reading and resetting of a day’s sales total.
X2/Z2 :
Allows  reading  or  resetting  sales  totals  in  a  specified
period.
 
  :
Switching off the display to prevent key board entries.
(The setting turn off the AC power.)
 
  :
After-transaction voiding (void mode)
4. Display
1) Layout
Operator display
Fig. 4-1
7 segment display (LED)
No. of positions
10
Color of display
Yellow Green
Character size
14.2 (H) 
 8.0 (W) mm
Customer display (Pop-up type)
Fig. 4-2
7 segment display (LED)
No. of positions
7
Color of display
Yellow Green
Character size
14.2 (H) 
 8.0 (W) mm
Display contents
<Segment>
Display
Position
Description
Amount
1-8
Minus sign 
4-10
– : Floating
Display
Position
Description
Error
8-10
Exx : xx = Error code
PGM Mode
10
TL/NS
CH, CR
10
: Lights up when a registration is
finalized by depressing TL/NS,
CH, CR key
SUB TOTAL/
short tender
10
: Light up when the subtotal is
displayed or when the amount
tendered is smaller
Change
10
: Light up when the change due
amount appears in the display.
Department
9-10
No zero-suppressed
PLU
8-10
No zero-suppressed
Repeat
8
Endless count, starting from 2.
Cashier No.
2
–x– : Cashie No.
Receipt OFF
9
_
CCD
compulsory
10
: Light up when CCD is compulsory
EJ full
8 - 10
: Light up when EJ memory is FULL
at the timming of key entry (by
PGM selection).
currency
conversion
10
: Light up when the EX key is
pressed to calculate a subtotal in
foreign currency.
<Decimal Point>
Display
Position
Description
Decimal point 
4-1
TAB
4-1
EJ near full
8, 9
(at the timing of finalization of a
transaction) (by PGM selection)
Power save
mode
10
Power save mode
Error code list
No.
Description
01
Registration error
02
Misoperation error
03
Desired code is not programmed yet
04-06
( not used )
07
Memory is full
08-10
( not used )
11
Compulsory of pushing the SBTL key
12
Compulsory of tendering
13-21
( Not used )
22
Over lapped cashier error
23
Cashier resetting over error
24-31
( Not used )
32
The cashier is not assigned
33
( Not used )
34
Overflow limitation
35
The open price entry is inhibited
36
The unit price entry is inhibited
37
The direct non-tendering finalization after previous
tender entry is inhibited.
38-66
( Not used )
67
REG Buffer full (ST VOID is inhidited)
68-85
( not used )
86
Communication error (ECR data copy)
87
Data error (ECR data copy)
88
Time out error (ECR data copy)
RCPT
OFF
DEPT
REPEAT
PLU/SUB
Page of 51
Display

Click on the first or last page to see other ER-A220 (serv.man2) service manuals if exist.