Read Panasonic TX-34P300K / TX-34P300XM / TX-34P300XX Service Manual online
1.4.
X-Radiation
Warning :
1. The potential sources of X-Radiation in TV sets are the
High Voltage section and the picture tube.
2. When using a picture tube test jig for service, ensure
that jig is capable of handling 32.0kV without causing X-
Radiation.
Radiation.
Note :
It is important to use an accurate periodically calibrated high
voltage meter.
voltage meter.
1. Set the brightness to minimum.
2. Measure the High Voltage. The meter reading should
indicate 31.0 ± 1 kV. If the meter indication is out of
tolerance, immediate service and correction is required to
prevent the possibility of premature component failure.
tolerance, immediate service and correction is required to
prevent the possibility of premature component failure.
3. To prevent an X-Radiation possibility, it is essential to use
the specified picture tube.