2 Specifications
2.1.
CU-3E18JBE
Note
• Specifications are subject to change without notice for further improvement.
Item
Unit
OUTDOOR UNIT
Indoor Unit Combination
 2.2kW + 2.8kW + 4.0kW
Power Source
1 Phase, 230V, 50Hz (Power supply from outdoor unit)
Cooling Operation
Capacity
kW
5.2 (1.8 ~ 7.3)
Electrical 
Data
Running Current
A
5.3
Power Input
kW
1.20 (0.36 ~ 2.18)
EER
W/W
4.33 (5.00 ~ 3.35)
Noise
Sound Pressure Level
dB-A
46
Sound Power Level
dB
60
Heating Operation
Capacity
kW
6.8 (1.6 ~ 8.3)
Electrical 
Data
Running Current
A
6.5
Power Input
kW
1.40 (0.32 ~ 2.11)
COP
W/W
4.86 (5.00 ~ 3.93)
Noise
Sound Pressure Level
dB-A
47
Sound Power Level
dB
61
Maximum Current
A
15.2
Starting Current
A
6.5
Circuit Breaker Capacity
A
16
Dimension
Height
mm
795
Width
mm 875 
(+95)
Depth
mm 320
Net Weight
kg
71
Connection Cable
3 + 1 (Earth) ø1.5 mm
2
Pipe Length Range (1 room)
m
3 ~ 25
Maximum Pipe Length (Total Room)
m
50
Refrigerant Pipe Diameter
Liquid Side
mm
6.35
Gas Side
mm
9.52
Compressor
Type
Scroll Type
Motor Type
DC Brushless (4-poles)
Rated Output
W
1.30k
Air Circulation
Type
Propeller Fan
Motor Type
DC Brushless (8-poles)
Rated Output
W
60
Fan Speed
High
RPM
580
Heat Exchanger
Type
Plate fin configuration forced draft type
Tube Material
Copper
Fin Material
Aluminum
Row/Stage
2/36
FPI
19
Air Volume
High
m
3
/min
41.7
Refrigerant Control Device
Expansion Valve
Refrigerant Oil
POE (RB-68A)
Refrigerant (R410A)
g
2640
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
Minimum
16
Outdoor Operation Range
Cooling
Maximum
46
26
Minimum
-10
Heating
Maximum
24
18
Minimum
-15
-16