LB-D2460HL - LG Air Conditioner Service Manual (repair manual). Page 7

Read LG LB-D2460HL Service Manual online

Refrigeration Cycle Diagram
• MODEL: LB-D2460HL
(
■ 
Rated performance for refrigerant line length of: 7.5m)
For installation over rated distance, 60g of refrigerant should be added for each meter.
ex) When installed at a distance of 15m, 450g of refrigerant should be added.
(15-7.5) x 60g = 450g
Pipe size(Diameter: ø)
Piping length(m)
Elevation(m)
MODEL
Gas
Liquid
Rated
Max.
Rated
Max.
LB-D2460HL
5/8"
3/8"
5
25
5
8
60
INDOOR UNIT
OUTDOOR UNIT
HEAT
EXCHANGER
HEAT
EXCHANGER
COMPRESSOR
GAS SIDE
LIQUID SIDE
COOLING
HEATING
REVERSING
VALVE
CHECK VALVE
CAPILLARY TUBE
–7–
Additional
refrigerant
(g/m)
Page of 40
Display

Click on the first or last page to see other LB-D2460HL service manuals if exist.