AURA (serv.man5) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 4

Read Harman Kardon AURA (serv.man5) EMC - CB Certificate online

Report No.: EM201300550-14        Application No.:
 
ZJ00032797        Page 4 of 58 
1. TEST RESULT SUMMARY   
Transmitter Part 
Test Item 
Test Requirement
Test Method 
Limit / Severity 
Result 
Equivalent 
isotropic 
radiated power 
EN 300 328:2006 
V1.7.1 clause 4.3.1
EN 300 328:2006 
V1.7.1 clause 5.7.2
20dBm(100mW) 
e.i.r.p. 
PASS 
Frequency 
Range 
EN 300 328:2006 
V1.7.1 clause 4.3.3
EN 300 328:2006 
V1.7.1 clause 5.7.4
2.4G to 
2.483GHz 
PASS 
Dwell Time 
EN 300 328:2006 
V1.7.1 clause 4.3.4.1
EN 300 328:2006 
V1.7.1 clause 
4.3.4.1 
Max 0.4s 
PASS 
Hopping 
channel 
separation 
EN 300 328:2006 
V1.7.1 clause 4.3.4.2
EN 300 328:2006 
V1.7.1 clause 
4.3.4.2 
1MHz PASS 
Hopping 
sequence 
EN 300 328:2006 
V1.7.1 clause 4.3.4.3
EN 300 328:2006 
V1.7.1 clause 
4.3.4.3 
At least 15 
hopping channels 
PASS 
Medium access 
protocol 
EN 300 328:2006 
V1.7.1 clause 4.3.5
EN 300 328:2006 
V1.7.1 clause 4.3.5
/ PASS 
Spurious 
Emission from 
Tx 
EN 300 328:2006 
V1.7.1 clause 4.3.6
EN 300 328:2006 
V1.7.1 clause 5.7.5
Table 2 & 3 
PASS 
Receiver Part 
Spurious 
Emission from 
Rx 
EN 300 328:2006 
V1.7.1 clause 4.3.7
EN 300 328:2006 
V1.7.1 clause 5.7.6
Table 4 & 5 
PASS 
Page of 58
Display

Click on the first or last page to see other AURA (serv.man5) service manuals if exist.