1-15
61
Adjusting the picture
A
d
ditio
nal Op
er
atio
ns
Adjusting the picture
Adjusting the tracking
Although the VCR automatically adjusts the tracking 
when playing a tape (the  indicator flashes in the 
display window, then turns off), distortion may occur 
if the recording is in poor condition.  In this case, 
manually adjust the tracking.
Press TRACKING +/– to display the tracking meter.  
The distortion should disappear as you press one of 
the two tracking buttons (the 
 indicator lights up).  
To resume automatic tracking adjustment, eject the 
tape and reinsert it.
About the Reality Regenerator (Reality Regenerator) function
The Reality Regenerator function automatically restores the picture to its original 
quality during playback.
To use the Reality Regenerator function
To turn it off, select NO in step 3.  The RR indicator turns off in the display window.
1
Press MENU, then select OPCIONES and press OK.
2
Press 
M/m to highlight PRÓXIMA, then press OK.
3
Press  
M/m to highlight REALITY REGENERATOR on PÁGINA2 of the 
OPCIONES menu, then press OK.
4
Press  
M/m to set REALITY REGENERATOR to SI, then press OK.
The RR indicator lights up in the display window.
5
Press MENU to return to the original screen.
SEGUIMIENTO NORMAL
Tracking meter
OPCIONES
REALITY REGENERATOR
APC
SENSOR DEL CABEZAL
NITIDEZ
NO
SI
ANTERIOR
VOLVER
AJUSTAR
:
SELECCIONAR
:
OK
MENU
PARA SALIR
:
2
PÁGINA
continued
62
Adjusting the picture
About the Adaptive Picture Control (APC) function
The Adaptive Picture Control (APC) function automatically improves recording and 
playback quality by adjusting the VCR to the condition of the video heads and tape.  
To maintain better picture quality, we recommend that you set APC to SI on 
PÁGINA2 of the OPCIONES menu (The APC indicator lights up in the display 
window).  For details, see page 64.
APC playback
The APC function automatically works on all types of tapes, including rental tapes 
and tapes that were not recorded with APC.
APC recording
Whenever you insert a tape and first start recording, the VCR adjusts to the tape using 
the APC function (the APC indicator flashes rapidly).  This adjustment is retained 
until the tape is ejected.
Notes
• The auto tracking adjustment cannot be guaranteed to work with tapes recorded in the LP 
mode on other VCRs.
• The APC function does not work if the tape speed is automatically changed from the SP to 
EP mode during a timer recording when VEL. AUTO. CINTA is set to SI in the OPCIONES 
menu, unless the tape has been recorded in the EP mode with the APC function.
• There is a delay of about ten seconds before the VCR actually starts recording while the VCR 
analyzes the tape.  To avoid the delay, first set the VCR to recording pause (the APC indicator 
flashes slowly) and press z REC to have the VCR analyze the tape (the APC indicator 
flashes rapidly) and return to recording pause.  After the APC indicator stops flashing, press 
X PAUSE to start recording immediately.
If you want to start recording quickly without using the APC function, first set the VCR to 
recording pause (the APC indicator flashes slowly) and press  X PAUSE again to start 
recording.
63
Changing menu options
A
d
ditio
nal Op
er
atio
ns
Changing menu options
Menu choices
Initial settings are indicated in bold print.
PÁGINA1
1
Press MENU, then select OPCIONES and press OK.
2
Press 
M/m to highlight the option to change, then press OK.
To go to PÁGINA2, highlight PRÓXIMA and press OK.  To return to PÁGINA1, 
highlight ANTERIOR and press OK.
3
Press 
M/m to change the setting, then press OK.
To adjust the sharpness, press 
</, and press OK.
4
Press MENU to return to the original screen.
Menu option
Set this option to
SELEC. AUTO. ANT.
SI
 if your TV is connected only to VHF/UHF OUT on the 
VCR.  To play a tape, set the TV to the VCR channel (channel 
3 or 4).
• NO if your TV is connected to both VHF/UHF OUT and LINE 
OUT on the VCR.  To play a tape, set the TV to the VCR input.
ESTEREO AUTO.
SI
 to receive stereo programs.
• NO to reduce noise.  The sound changes to monaural.
SINTONIZ. AUDIO
MAIN
 to record the main sound on both hi-fi and normal audio 
tracks.
• SAP to record the SAP (Second Audio Program) sound on both 
hi-fi and normal audio tracks.
SELC. DE CINTA
AUTO
 when using a T-160 length tape or any tape shorter than 
a T-140 length tape.
• 180 when using a T-140 or T-180 length tape.
For details, see page 36.
VEL. AUTO. CINTA
SI
 to change the timer recording tape speed automatically to 
the EP mode when the remaining tape length becomes shorter 
than the recording time.  To operate VEL. AUTO. CINTA, set 
SELC. DE CINTA correctly.
• NO to keep the same tape speed.
OPCIONES
ESTEREO AUTO.
SELEC. AUTO. ANT.
SINTONIZ. AUDIO
SELC. DE CINTA
SI
MAIN
SI
AUTO
VEL. AUTO. CINTA
SI
PRÓXIMA
VOLVER
AJUSTAR
:
SELECCIONAR
:
OK
MENU
PARA SALIR
:
1
PÁGINA
OPCIONES
REALITY REGENERATOR
APC
SENSOR DEL CABEZAL
NITIDEZ
SI
SI
SI
ANTERIOR
VOLVER
AJUSTAR
:
SELECCIONAR
:
OK
MENU
PARA SALIR
:
2
PÁGINA
B
A
continued
64
Changing menu options
PÁGINA2
Menu option
Set this option to
APC
SI
 to switch on the APC (Adaptive Picture Control) function 
and improve picture quality.
• NO to switch off APC.
REALITY  
REGENERATOR
SI
 to switch on the Reality Regenerator (Reality Regenerator) 
function and restore the picture to its original quality during 
playback.
• NO to switch off Reality Regenerator.
SENSOR DEL 
CABEZAL
SI
 to allow the VCR to automatically check the condition of 
the video heads and inform you when they are dirty.
• NO to turn off the sensor.
NITIDEZ
• B (Low) through A (High) to adjust the sharpness of the 
picture.  Select B to turn off the sharpness control.