Read Sony SLV-E720EN (serv.man2) Service Manual online
SERVICE MANUAL
North European Model
RMT-V197
SLV-E720EN
SUPPLEMENT-1
File this supplement with the service manual.
Subject: EEP ROM INITIAL DATA INPUT
(99-012)
1. EEP ROM INITIAL DATA INPUT
When EEP ROM (IC472 on FR-119 board) was changed, make it
sure to input the data shown below and to perform both “2-3-1. RF
Switching Position/AF Switching Position Adjustment ”.
sure to input the data shown below and to perform both “2-3-1. RF
Switching Position/AF Switching Position Adjustment ”.
Input Method:
1) Connect the LANC jig (J-6090-051-A) to CN164 on MA-286
1) Connect the LANC jig (J-6090-051-A) to CN164 on MA-286
board.
2) Turn on the power.
3) Input Data: 80 in Address: 00 on Page: 1.
4) Input data on Page F as following table.
3) Input Data: 80 in Address: 00 on Page: 1.
4) Input data on Page F as following table.
5) Turn off the power
6) Disconnect the adjusting remote commander and LANC jig
6) Disconnect the adjusting remote commander and LANC jig
from the connector (CN164).
Note:
When connecting or disconnecting LANC jig to CN164 on
MA-286 board, first connect the adjusting remote com-
mander (J-6082-053-B) to the jack on LANC jig before
connecting LANC jig to CN164. Connection or disconnec-
tion of the adjusting remote commander in the condition
LANC jig is connected to CN164 causes IC LINK (PS001)
to damage itself.
MA-286 board, first connect the adjusting remote com-
mander (J-6082-053-B) to the jack on LANC jig before
connecting LANC jig to CN164. Connection or disconnec-
tion of the adjusting remote commander in the condition
LANC jig is connected to CN164 causes IC LINK (PS001)
to damage itself.
Sony Corporation
Home Video Company
9-921-649-81
99I05070-1D
Printed in Japan © 1999. 9
Published by Quality Assurance Dept.
Page
Address
B6
B5
94
93
02
01
F
Data
10
60
01
20
05
04
Display