GV-D200 - Sony VCR Service Manual (repair manual). Page 120

Read Sony GV-D200 Service Manual online

5-30
3. IR Audio Deviation Adjustment (VC-250 board)
Mode
VTR stop
Signal
Video : No signal
Audio : –400Hz, –7.5dBs, Audio left
and right terminal of AUDIO/VIDEO
jack
Measurement Point
AUDIO L terminal and AUDIO R
terminal of IR receiver jig
(Terminated at 47k
)
Measuring Instrument
Audio level meter
Adjustment Page
F
Adjustment Address
7F
Specified Value
Signal level: –7.5 ± 1.0 dBs
Level difference of L and R: Below
2dB
Connection of Equipment:
Connect the measuring device as shown in the following figure,
and adjust.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
Connect the audio level meter to
the AUDIO L terminal of the IR
receiver jig.
3
F
7F
Change the data and set the
400Hz audio signal level to the
specified value.
4
F
7F
Press PAUSE button.
5
Connect the audio level meter to
the AUDIO R terminal of the IR
receiver jig.
6
F
7F
Check that the 400Hz audio
signal level is within the
specified value. If outside, repeat
from step 2.
7
0
01
00
Set the data.
Main unit
Audio oscillator
Audio Left
(White)
Video
(Yellow)
Audio Right
(Red)
Attenuator
AUDIO/VIDEO
INPUT
IR receiver jig
AUDIO OUT
L
R
Audio level meter
47k 
600 
600 
: 270 
 (1-249-410-11) + 330 
 (1-249-411-11)
47k 
 (1-249-437-11)
Fig. 5-3-17.
Page of 127
Display