– 28 –
KV
-XF34K94
RM-962
REMOVAL OF ANODE-CAP
NOTE : After removing the anode, short circuit the anode of the picture tube and
the anode cap to the metal chassis, CRT shield or carbon paint on the
CRT.
REMOVING PROCEDURES
1
Do not damage the surface of anode-caps with sharp shaped objects.
2
Do not press the rubber too hard so as not to damage the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built into the rubber.
3
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the rubber.
HOW TO HANDLE AN ANODE-CAP
3
When one side of the rubber cap is separated from the anode button,  the anode-cap
can be removed by turning up the rubber cap and pulling it up in the direction of the
arrow 
c
.
2
Using a thumb pull up the rubber cap firmly in the direction indicated by the arrow 
b
.
1
Turn up one side of the rubber cap in the direction indicated by the arrow 
a
.
2-12. PICTURE TUBE REMOVAL
Four DGC clips
DGC holder
!™
Demagnetic coil
0
Four claws
1
Four screws 
(washer head)
(+P 4 
× 
16)
3
Four screws 
(washer head)
(+P 4 
× 
16)
2
Speaker Bracket
assy (L)
4
Speaker Bracket
assy (R)
Nut, 
special CRT
Nut, 
special CRT
Cap, screw
Cap, screw
6
Chassis assy
9
Deflection
yoke
8
Neck assy
7
C board
5
Anode cap
!∞
Picture tube
Two DGC bands
Cushion
Tension
spring
!•
Cushion
DGC
a
a
b
b
c
Anode button
Page of 65