Read Sony KV-XF34K94 Service Manual online
– 28 –
KV
-XF34K94
-XF34K94
RM-962
•
REMOVAL OF ANODE-CAP
NOTE : After removing the anode, short circuit the anode of the picture tube and
the anode cap to the metal chassis, CRT shield or carbon paint on the
CRT.
CRT.
•
REMOVING PROCEDURES
1
Do not damage the surface of anode-caps with sharp shaped objects.
2
Do not press the rubber too hard so as not to damage the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built into the rubber.
A metal fitting called the shatter-hook terminal is built into the rubber.
3
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the rubber.
The shatter-hook terminal will stick out or damage the rubber.
•
HOW TO HANDLE AN ANODE-CAP
3
When one side of the rubber cap is separated from the anode button, the anode-cap
can be removed by turning up the rubber cap and pulling it up in the direction of the
arrow
can be removed by turning up the rubber cap and pulling it up in the direction of the
arrow
c
.
2
Using a thumb pull up the rubber cap firmly in the direction indicated by the arrow
b
.
1
Turn up one side of the rubber cap in the direction indicated by the arrow
a
.
2-12. PICTURE TUBE REMOVAL
!¡
Four DGC clips
!¶
DGC holder
!™
Demagnetic coil
0
Four claws
1
Four screws
(washer head)
(+P 4
(washer head)
(+P 4
×
16)
3
Four screws
(washer head)
(+P 4
(washer head)
(+P 4
×
16)
2
Speaker Bracket
assy (L)
assy (L)
4
Speaker Bracket
assy (R)
assy (R)
!¢
Nut,
special CRT
special CRT
Nut,
special CRT
special CRT
Cap, screw
Cap, screw
6
Chassis assy
9
Deflection
yoke
yoke
8
Neck assy
7
C board
5
Anode cap
!∞
Picture tube
!§
Two DGC bands
Cushion
!¢
!£
Tension
spring
spring
!•
Cushion
DGC
DGC
a
a
b
b
c
Anode button
Click on the first or last page to see other KV-XF34K94 service manuals if exist.