KV-TG212M50 - Sony TV Service Manual (repair manual). Page 11

Read Sony KV-TG212M50 Service Manual online

– 11 –
KV-TG212M50/TG212M80
RM-W101
SCREEN
FOCUS
165 
± 2VDC
2-3.
FOCUS ADJUSTMENT
FOCUS adjustment should be completed before the W/B
adjustment:
1. Receive digital monoscope pattern.
2. Set picture mode: DYNAMIC.
3. Adjust focus VR to obtain a just focus at the center of
the screen.
4. Change receiving signal to white pattern and blue
back.
5. Confirm MAGENTA RING is not noticeable. Incase
magenta ring is obvious, then adjust FOCUS VR to
balance magenta ring and FOCUS.
2-4.
G2 (SCREEN) ADJUSTMENTS
1. Set the PICTURE & BRIGHTNESS to STANDARD.
2. Put the Video input mode signal.
3. Connect R,G,B of the C board cathode to
oscilloscope.
4. Adjust Brightness to obtain the cathode value to
value below.
5. Adjust G2 (screen) on the FBT until picture shows
the point before cut off.
2-5.
WHITE BALANCE ADJUSTMENT
1. Set to Service Mode (Refer Section 3-1:
ADJUSTMENTS WITH COMMANDER)
2. Input white raster signal.
3. Set Picture to <DYNAMIC mode>
4. Select RDRV (002) with 1 and 4 and fixed the
value to 37 dec with 3 and 6.
5. Adjust WHBL GDRV (003) and BDRV (004) with 1
and 4 and adjust the data with 3 and 6 for best
white balance in Highlight condition.
6. Write into the memory by pressing [MUTING] then -.
7. Adjust WHBL BKOR (000) and BKOG (001) with 1
and 4 and adjust the level with 3 and 6 for best
white balance cut-off condition.
8. Write into memory by pressing [MUTING] then -.
2-6.
SUB BRIGHT ADJUSTMENT
1. Set to service mode.
2. Brightness set to 50%, Picture....Minimum
3. Select WHBL 010 "SBRT" with 1 and 4 and adjust
010 "SBRT" data with 3 and 6 so that the third
stripe from right dimly lit.
4. Write into the memory by pressing [MUTING] then -.
5. GA models Cut-off
: 10 IRE
Slightly Glimmer : 20 IRE
FLYBACK TRANSFORMER  (T802-14")
FLYBACK TRANSFORMER  (T801-21")