KV-SW212M60 - Sony TV Service Manual (repair manual). Page 6

Read Sony KV-SW212M60 Service Manual online

– 6 –
KV-SW212M60/M80/M80/H/P52
   RM-GA002
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or
carbon paint on the CRT.
• REMOVING PROCEDURES
Turn up one side of the rubber cap in the direction
indicated by the arrow a.
Using a thumb pull up the rubber cap firmly in the direction
indicated by the arrow b.
When one side of the rubber cap is separated from the
anode button,  the anode-cap can be removed by turning
up the rubber cap and pulling it up in the direction of the
arrow 
c.
• HOW TO HANDLE AN ANODE-CAP
Do not damage the surface of anode-caps with sharp
shaped objects.
Do not press the rubber too hard so as not to damage
the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built
into the rubber.
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the
rubber.
A
A
B
B
C
 Anode Button
1-7
PICTURE TUBE  REMOVAL
Note:
• Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom right
and left.
1) Remove the Rear Cover.
2) Unplug all interconnecting leads from the Deflection Yoke, Neck Assy, Degaussing Coils and CRT grounding strap. Remove
Chassis Assy.
3) Place the TV set with the CRT face down on a cushion (jig).
qs
Screw, Tapping 5 + Crown Washer (x4) 
4
 
Anode Cap Removal
9
 
Degaussing Coil
6
 
Loosen the Neck Assembly 
fixing screw and remove
Neck Assy & VM board
7
Loosen the Deflection Yoke
fixing screw and remove
5
 
C Board Removal
qa
 
Spring Tension
Removal (x2)
8
 
Holder, DGC
Removal (x2)
0
 
Earth Coating Assy
Page of 62