Read Sony KV-SP29M89K Service Manual online
– 9 –
KV-SP29M89K
RM-GA002
Moved RV750 (H.STAT)
R
R
G
G
B
B
A
A
B
B
B
B
R
G
G
R
B
2-2. CONVERGENCE ADJUSTMENT
Preparation:
• Before starting, perform FOCUS adjustment.
• Picture Mode "SOFT"
• Receive dot/cross hatch pattern.
• Before starting, perform FOCUS adjustment.
• Picture Mode "SOFT"
• Receive dot/cross hatch pattern.
1. (Moving vertically), adjust the 4 pole magnet to converge
red, green and blue dots in the center of the screen.
2. Tilt the 4 pole magnet and adjust static convergence
to open or close the 4 pole magnet.
3. When the 4 pole magnet is moved in the direction of
arrow A and B, the red, green and blue dots moves
as shown below:-
as shown below:-
a) Vertical Static Convergence
b) Horizontal Static Convergence
If the blue dots does not converge with the red and
green dots, use the 6 pole magnet to adjust in
the manner described below:-
If the blue dots does not converge with the red and
green dots, use the 6 pole magnet to adjust in
the manner described below:-
c) Y Separation axis correction magnet adjustment.
1. Receive cross hatch signal.
2. Set Picture to "MINIMUM", Brightness to
2. Set Picture to "MINIMUM", Brightness to
"STANDARD".
3. Adjust the Y separation axis correction magnet on
the Neck Assembly so that the horizontal lines at
the top and bottom of the screen are straight.
the top and bottom of the screen are straight.
Red
Blue
Red
Blue
6 Pole Magnet
4 pole Magnet
DY pocket
Purity
6 Pole
Magnet
4 Pole
Magnet
R G
B
R
G
B
R
G B
R
B
R
G
G
G
B
R
B
4 pole magnet
RV750
H. STAT
H. STAT
RV1800
G2 (SCREEN)
G2 (SCREEN)
Center dot
R G B
G
R
B