KV-PG14M40 (serv.man2) - Sony TV Service Manual (repair manual). Page 4

Read Sony KV-PG14M40 (serv.man2) Service Manual online

– 4 –
KV-PG14M40
RM-952
The units in this manual contain a self-diagnosis function. If an error occurs, the STANDBY (
1
) indicator will automati-
cally begin to flash. A description of the self diagnosis function is explained in the instruction manual.
The number of times the STANDBY (
1
) indicator flashes translates to a probable source of the problem. If an error
symptom cannot be reproduced, the remote commander can be used to review the failure occurrence data stored in
memory to reveal past problems and how often these problems occur.
1. DIAGNOSIS TEST INDICATORS
When an errors occurs, the STANDBY (
1
) indicator will flash a set number of times to indicate the possible cause of the
problem. If there is more than one error, the indicator will identify the first of the problem areas.
Result for all of the following diagnosis items are displayed on screen. No error has occured if the screen displays a “0”.
Diagnostic
Item
Description
• Power does not
turn on
• +B overcurrent
(OCP)
• Horizontal
deflection
overdrive
• White balance
failure (no
PICTURE)
• Vertical deflection
stopped
• Micro reset
Detected
Symptoms
• Power does not come on.
• No power is supplied to
the TV.
• AC power supply is faulty.
• Power does not come on.
• Load on power line is
shorted.
• Has entered standby state
after horizontal raster.
• Power line is shorted or
power supply is stopped.
• Vertical deflection pulse
 is stopped
• Power is shut down
shortly, after this return
back to normal.
• Detect Micro latch up.
Note 1: If a + B overcurrent is detected, stoppage of the vertical deflection is detected simultaneously.
The symptom that is diagnosed first by the microcontroller is displayed on the screen.
Note 2: Refer to screen (G2) Adjustment in section 3-4 of this manual.
SELF DIAGNOSIS FUNCTION
No. of times
STANDBY (
1
)
lamp flashes
Does not light
2 times
4 times
Self-diagnostic
display/Diagnostic
result
002:000 or
002:001~255
004:000 or
004:001~225
101:00 or
101:001~225
Probable
Cause
Location
• Power cord is not
plugged in.
• Fuse is burned out
F4601 (F)
• H.OUT Q801 is shorted.
(A board)
• -13V is not supplied.
(A board)
• IC 551 faulty (A board)
• Discharge CRT
(C Board)
• Static discharge
• External noise
Page of 41