KV-HZ29M65 - Sony TV Service Manual (repair manual). Page 6

Read Sony KV-HZ29M65 Service Manual online

– 6 –
KV-HZ29M65/HZ29M85/HZ29M90/HZ34M85
RM-1008
RM-1008
RM-1008
RM-1008
3.
Blinking count display of    1    indicator
Lamp OFF : 
3.0 seconds
Lamp ON : 0.3 seconds
Lamp OFF : 0.3 seconds
Release of    1    indicator blinking.
The STAND BY indicator blinking display is released by turning OFF the power switch 
on the TV main unit or removing the plug from the power.
But in the RLY ERR (10 times blinking), do not release by tuning power off.
For details, refer to the item 1-6.
* One blink is not used for self-diagnosis.
•EXAMPLE
<Diagnosis Items>  <Number of Blinks>
• +B overcurrent  
2 times
• +B overvoltage
3 times
• Vertical deflection stop
4 times
< FRONT PANEL >
1   indicator
AUTO PROG
MENU
L(MONO)
R
4
PROG
4.
Self-diagnosis screen displays
In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when
the screen disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether
the detection circuit operated or not) in order to allow confirmation.
<Screen Display Method>
Quickly press the remote command button in the following order from the standby state.
   
˘
   Be aware that this differs from the method of 
   entering the service mode (            +   ).
   
b  
   
b  
   
b  
5
=/1
•  "G" : OK, "NG" : DETECTS ONCE OR MORE
•  THE 10 DIGITS OF NUMERALS ARE FOR CHECKING,
      NO RELATION TO DIAGNOSIS.
•  101 : NO LED BLINKING FOR WDT.
    "0" : NUMBER OF DETECTION.
Self-diagnosis screen display
Page of 127
Display

Click on the first or last page to see other KV-HZ29M65 service manuals if exist.