Read Sony KV-HR32K90 Service Manual online
– 7 –
KV-HR32K90
RM-1012
5.
After the self-diagnosis operation
•
The results display is not automatically cleared. In case of repairs and after repairs, check the self-diagnosis screen and be sure
to return the results display to “ 0 ”.
•
If the results display is not returned to “ 0 ” it will not be possible to judge a new malfunction after completing repairs.
<Method of Clearing Results Display>
<Method of Ending Self Diagnosis Screen>
•
When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main unit.
1. Power off (Set to the standby mode)
2.
(Service Mode)
3. Channel 8 b 0 (Test reset = Factory preset condition)
AUDIO PROT
(FROM A BOARD)
LOW-B ERR
(FROM A BOARD)
HV-PROT
(FROM D BOARD)
AC-RLY
(TO A BOARD)
OCP
(FROM A, D BOARD)
MAIN MICRO-
COMPUTER
IC0001
12C BUS
COMPONENT I/F IC0401
CXA-2170Q
OVP
HV PROT
OCP
AKB
H-ST
OP
V
-ST
OP
PF
MICRO-
COMPUTER
IC0002
OVP
(FROM A, D BOARD)
12C BUS
• I2C YCJ RETURN DATA
1
1
1
1
1
1
1
1
LED
BLINKING
TIMES
MG BOARD
SYMPTOM
2
3
4
5
6
7
8
9
3
4
5
6
7
8
9
10
+B OCP
+B OVP
V-STOP
AKB
LOW-B ERROR
H-STOP
AUDIO PROT
Z DET
HV PRT
+B OVP
V-STOP
AKB
LOW-B ERROR
H-STOP
AUDIO PROT
Z DET
HV PRT
Click on the first or last page to see other KV-HR32K90 service manuals if exist.