Read Sony KV-HP213M93 Service Manual online
– 15 –
KV-HP213M93
RM-GA002
2-14. HV Cap Assy dressing
180 ± 5 mm
HV Cable Holder
SAFETY OPERATION
CAUTION:
OK
NG
Ensure HV Holder is beside
DGC to keep further distance
from HV Cable
DGC to keep further distance
from HV Cable
distance > 1mm/kV
distance < 1mm/kV
Purse Lock
HV Holder
HV Cable
Dress HV Cable at inner ring
45º
B
A
A
A
A
C
Dress HV Holder
Combi with Purse
Lock Ø9 as shown
Combi with Purse
Lock Ø9 as shown
CAUTION:
Keep HV cable facing inwards DY to keep HV cable away
from ventilation side of rear cover -->
Keep HV cable facing inwards DY to keep HV cable away
from ventilation side of rear cover -->
10mm or more.
Ensure TVSR
1mm/kV is kept from HV cable to DY &
other conductive parts
TVSR (Clause 9.4.7)
:
A) Spacing between HV cable and conductive part's
surface -->
1mm/kV or more
B) Spacing between edge of anode cap and conductive
parts -->
0.5mm/kV or more
C) Spacing between HV cable & enclosure with
ventilation (i.e. Rear Cover side) -->
10mm or more
Place purse lock Ø9 after the exit of DGC
Conn from DGC
Conn from DGC
Gate (2 positions)
of HV holder
DGC
Purse Lock Ø9
DGC Conn
outlet
Black tape
2-15. AC Power Cord dressing
Purse Lock Ø8
Dress AC Power Cord with
purse lock at rear cover
AC Cord Holder
AC Power Cord
Make sure AC Power Cord is dressed
between bottom cover boss and rail guide