KV-HP213M93 - Sony TV Service Manual (repair manual). Page 16

Read Sony KV-HP213M93 Service Manual online

– 15 –
KV-HP213M93
   RM-GA002
2-14.  HV Cap Assy dressing
180 ± 5 mm
HV Cable Holder
SAFETY OPERATION
CAUTION:
OK
NG
Ensure HV Holder is beside 
DGC to keep further distance 
from HV Cable
distance > 1mm/kV
distance < 1mm/kV
Purse Lock 
 
HV Holder 
HV Cable
Dress HV Cable at inner ring
45º
B
A
A
A
A
C
Dress HV Holder
Combi with Purse
Lock Ø9 as shown
CAUTION:
Keep HV cable facing inwards DY to keep HV cable away
from ventilation side of rear cover --> 
10mm or more.
Ensure TVSR 
1mm/kV is kept from HV cable to DY &
other conductive parts
TVSR (Clause 9.4.7) 
:
A) Spacing between HV cable and conductive part's
 
surface --> 
1mm/kV or more
B) Spacing between edge of anode cap and conductive
 
parts --> 
0.5mm/kV  or more
C) Spacing between HV cable & enclosure with
 
ventilation (i.e. Rear Cover side) --> 
10mm  or more
      
  
    
Place purse lock Ø9 after the exit of DGC 
Conn from DGC
Gate (2 positions)
of HV holder
DGC
Purse Lock Ø9
DGC Conn
outlet
Black tape
2-15.  AC Power Cord dressing
Purse Lock Ø8
Dress AC Power Cord with
purse lock at rear cover
      
  
    
AC Cord Holder
AC Power Cord
Make sure AC Power Cord is dressed
between bottom cover boss and rail guide
Page of 68
Display

Click on the first or last page to see other KV-HP213M93 service manuals if exist.