KV-DX32K9H - Sony TV Service Manual (repair manual). Page 5

Read Sony KV-DX32K9H Service Manual online

– 5 –
KV-DX32K9H/KV-DX32K9H/B
RM-1006
RM-1006
3.
Blinking count display of STANDBY/                indicator
1.
Summary of Self-Diagnosis Function
This device includes a self-diagnosis function.
In case of abnormalities, the STANDBY/                  indicator automatically blinks.  It is possible to predict the abnormality
location by the number of blinks.  The Instruction Manual describes blinking of the /STANDBY/                 indicator.
If the symptom is not reproduced sometimes in case of a malfunction, there is recording of whether a malfunction was generated
or not.  Operate the remote command to confirm the matter on the screen and to predict the location of the abnormality.
2.
Diagnosis Items and Prediction of Malfunction Location
When a malfunction occurs the STANDBY/                 indicator only blinks for one of the following diagnosis items.  In case of
two or more malfunctions, the item which first occurred blinks.  If the malfunctions occurred simultaneously, the item with the
lower blink count blinks first.
The screen display displays the results regarding all the diagnosis items listed below.  The display “ 0 ” means that no malfunc-
tions occurred.
Lamp OFF : 
3.0 seconds
Lamp ON : 0.3 seconds
Lamp OFF : 0.3 seconds
Release of STANDBY/              indicator blinking.
The STAND BY indicator blinking display is released by turning OFF the power switch 
on the TV main unit or removing the plug from the power.
* One blink is not used for self-diagnosis.
¥EXAMPLE
<Diagnosis Items>  <Number of Blinks>
¥ +B overcurrent  
2 times
¥ +B overvoltage
3 times
¥ Vertical deflection stop
4 times
< FRONT PANEL >
STANDBY/                 indicator
Diagnosis Item
Number of times 
STANDBY/
indicator blinks
Probable Cause Location
Detected Symptoms
+B overcurrent (OCP)
2 times
T8001 (FBT) Rare short-circuit etc. (D6 board)  
Q5030 (H-OUT), Q5028 (D6 board)
Has entered standby mode. 
(Relay is off when the power 
turns on.)
+B overvoltage (OVP)
3 times
+B load open (D6 board)  R6570 Open  
PH6502, control system malfunction  L2603 
Open
Has entered standby mode. 
Vertical deflection stopped 
(V-STOP)
4 times
IC5004 (V. OUT) (D6 board) IC201 
(CXA2150Q)  (A6 board)
Has entered standby mode. 
IK error (AKB ERROR)
5 times
VIDEO OUT IC malfunction IC9001, 9002, 
9003 (C3 board)  IC201 (CXA2150Q)  
(A6 board)
Has not entered standby mode. 
Low-B error
6 times
Sub power supply system load shorted etc. 
(A6 board)
Has entered standby mode. 
Horizontal deflection 
stopped (H-STOP)
7 times
IC201 (CXA2150Q)  (A6 board)  Q5031 
(S-COR-OUT), Q5030 (H-OUT), Q5028
Has entered standby mode. 
SECTION 1
SELF DIAGNOSIS FUNCTION
Page of 114
Display