– 8 –
KV-AW212M50,M50/H,M63,M80,M80/H,M81,
M83,M83/H,N50,N60,N63/H,P50,P52
RM-GA002
SECTION 2
WIRE DRESSING
CAUTION :
1. Do not overpull the wires during dressing
1. Do not overpull the wires during dressing
--> avoid disconnection of wires.
2. Make sure wires are kept away from
sharp edges, heatsinks & other
high-temperature parts.
high-temperature parts.
2-1. Mount Caution on A/C
2-2.
Wiredressing on A board
CAUTION:
Dress & control mounted wires (Lead Assy, G2 & 200V
wire) on C board if necessary :
--> ensure wires do not get trapped during solder dip
process
--> ensure wires do not get punched by ICT jig (modify
ICT jig if applicable)
Dress & control mounted wires (Lead Assy, G2 & 200V
wire) on C board if necessary :
--> ensure wires do not get trapped during solder dip
process
--> ensure wires do not get punched by ICT jig (modify
ICT jig if applicable)
CN703:
Ensure Pin 1
is connected
to orange
wire (200V)
Ensure Pin 1
is connected
to orange
wire (200V)
W700:
Board-in Lead
Assy, G2
Board-in Lead
Assy, G2
CAUTION:
Ensure Lead Assy, G2 is kept away from leg of nearby
conductive parts during solder DIP process
--> to ensure insulation of wire does not get melted
when touching leg of part due to heat conduction from
solder bath.
Ensure Lead Assy, G2 is kept away from leg of nearby
conductive parts during solder DIP process
--> to ensure insulation of wire does not get melted
when touching leg of part due to heat conduction from
solder bath.
Lead Assy, G2 & 200V wire on C Board
FBT Flange
Lead Assy, Focus
FBT Flange
HV cable
Make sure rubber cap is
pushed
down to make sure it
covers
the FBT flange completely
Lead Assy, G2
R795/R760
Keep Lead Assy, G2
away from leg of conductive parts.
away from leg of conductive parts.
D750
C Board
Dress HV Holder
Combi with Purse
Lock ø9 as shown
Combi with Purse
Lock ø9 as shown
A
C
CN70
W70
Mounted Wire (DIP)
Plug (A/I)
CN801
Click on the first or last page to see other KV-AW212M50 service manuals if exist.