KV-34FV310 (serv.man2) - Sony TV Service Manual (repair manual). Page 6

Read Sony KV-34FV310 (serv.man2) Service Manual online

— 7 —
KV-34FV310/38FV310
SELF-DIAGNOSTIC FUNCTION
Display of Standby/Timer LED Flash Count
3 times
2 times
4 times
5 times
9 times
10 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
 
Diagnostic Item 
 
Flash Count*
 
+B Overcurrent 
 
2 times
 
+B Overvoltage 
 
3 times
 V-STOP 
  4 
times
 IK 
(AKB) 
  5 
times
 
Zero Cross 
 
9 times
 9V 
 
  10 
times
*One fl ash count is not used for self-diagnostic.
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to fl ash. The number 
of times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY/TIMER LED fl ash indicators is listed in the 
instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review 
the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will fl ash a set number of times to indicate the possible cause of the problem. If there is more than 
one error, the LED will identify the fi rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. If the screen displays a “0”, an error has occurred.
Self Diagnosis
Supported model
Diagnostic Item 
No. of times 
STANDBY / TIMER  
lamp flashes 
Probable Cause Location 
Detected Symptoms 
Power does not turn on  
Does not light 
•  Power cord is not plugged in. 
•  Fuse is burned out (F601).  
(GW Board) 
•  Power does not come on. 
•  No power is supplied to the TV. 
•  AC Power supply is faulty. 
+B overcurrent (OCP)* 
2 times 
•  H.OUT (Q502) is shorted. (A Board) 
•  IC702 is shorted. (C Board) 
•  Power does not come on. 
•  Load on power line shorted. 
+B overvoltage (OVP) 
3 times 
•  IC501 is faulty. (A Board) 
•  If a high is supplied to pin 2 of IC501. 
(A Board) 
•  Has entered standby mode. 
V-Stop 4 
times 
•  +12V is not supplied. (A Board) 
•  IC561 is faulty. (A Board) 
•  Has entered standby state after 
horizontal raster. 
•  Vertical deflection pulse is stopped. 
•  Power line is shorted or power 
supply is stopped. 
IK (AKB) 
5 times 
•  Video OUT (IC561) is faulty. (A Board) 
•  IC702 is faulty. (C Board) 
•  Screen (G2) is improperly adjusted. ** 
•  No raster is generated. 
•  CRT Cathode current detection 
reference pulse output is small. 
Zero Cross 
9 times 
•  No zero cross pulses on pin 45 
IC1001. (A Board) 
•  Power does not come on. 
9V Check  
10 times 
•  Relay failed (RY600) 
•  Power does not come on. 
*  If a +B overcurrent is detected, stoppage of the vertical deflection is detected simultaneously. The symptom that is diagnosed first 
by the microcontroller is displayed on the screen. 
** Refer to Screen (G2) Adjustments in Section 2-4 of this manual 
Page of 125
Display

Click on the first or last page to see other KV-34FV310 (serv.man2) service manuals if exist.