KV-34FS110 (serv.man2) - Sony TV Service Manual (repair manual). Page 7

Read Sony KV-34FS110 (serv.man2) Service Manual online

KV-34FS110/34FV210/38FS110/38FV210
KV-34FS110/34FV210/38FS110/38FV210 
8
Self-Diagnostic Screen Display
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confi rmed, it is possible to bring up past 
occurrences of failure on the screen for confi rmation.
To Bring Up Screen Test
In standby mode, press buttons on the Remote Commander sequentially, in rapid succession, as shown below:
DISPLAY
  
 Channel  5      
 Sound Volume  -  
 
 POWER
 
Self-Diagnostic Screen Display
 
SELF DIAGNOSTIC
2: +B 
OCP  0
3: +B 
OVP  N/A
4: VSTOP  0 
Numeral “0” means that no fault was detected.
5: AKB 
Numeral “1” means a fault was detected one time only.
101:   WDT 
N/A
Handling of Self-Diagnostic Screen Display
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen during repairs. When you 
have completed the repairs, clear the result display to “0”.
Unless the result display is cleared to “0”, the self-diagnostic function will not be able to detect subsequent faults after completion of the repairs.
Clearing the Result Display
To clear the result display to “0”, press buttons on the Remote Commander sequentially when the diagnostic screen is displayed, as shown below:
Channel  8  
  ENTER
Quitting the Self-Diagnostic Screen
To quit the entire self-diagnostic screen, turn off the power switch on the Remote Commander or the main unit.
Self-Diagnostic Circuit
MT BOARD
IC001
Y/CHROMA JUNGLE
AW BOARD
IC561
V. OUT
MT BOARD
IC001
SYSTEM
MT BOARD
IC002
MEMORY
IK-AKBIN
FROM
C BOARD
IC702 PIN 5
I-HLDWN
FROM
AW BOARD
IC501
PIN 1
72
O-LED
REF
I-Prot
IO-BDAT
BDA
DISPLAY
51
3
78
79
53
5
+B overcurrent (OCP) 
Occurs when an overcurrent on the +B (135V) line is detected by pin 72 of IC001 (MT Board). If the voltage of pin 72 of IC001 (MT Board) is less than 
1V when V.SYNC is more than seven verticals in a period, the unit will automatically turn off. 
I-Prot 
Occurs when an absence of the vertical defl ection pulse is detected by pin 78 of IC001 (MT Board). Power supply will shut down when waveform 
interval exceeds 2 seconds. 
IK (AKB) 
If the RGB levels* do not balance within 2 seconds after the power is turned on, this error will be detected by IC001 (MT Board). TV will stay on, but 
there will be no picture.
*(Refers to the RGB levels of the AKB detection Ref pulse that detects IK).
Note that this differs from entering the Service Mode (Sound Volume  +  ).