KV-34FQ75A - Sony TV Service Manual (repair manual). Page 6

Read Sony KV-34FQ75A Service Manual online

6
Device acknowledge is used to check IIC errors. Device acknowledge is checked by sending an IIC start sequence during CRT power on. Each
device is checked three times, if there is no acknowledge after each attempt, it will be regarded as an error.
There are three steps to check for errors.
1.
IIC line 0
If all devices except the NVM have errors, IIC line 0 error is displayed.
2.
Board check
If all devices mounted on one board have errors, board error is displayed.
3.
Each device check
If IIC line error and board error are not detected then the device with the error is displayed.
The detected errors can be displayed as follows :
1.
Error Monitor Menu.
2.
Error Reader.
Error Detection Monitor
1. Error Monitor Menu
Operating Time :
  
0000167     h     45    min
Stored Errors :
ERROR MONITOR
1.
A - B    TU1350,    Sub-Tuner
2.
J  - B    TDA9320,    Sub.  Col.   Dec.
3.        No Error Occured
4.        No Error Occured
5.
No Error Occured
Current Error :
   A-B.    TU1350,      Sub-Tuner
1. IGNORE ERRORS  
 OFF          ON          OFF
Last menu              Enter Item 
Page of 104
Display