Read Sony KV-34FQ75A Service Manual online
21
GREEN
BLUE
RED
(1) Screen centre convergence [Static convergence]
1.
Input a dot pattern signal from the pattern generator.
2.
Normalize the picture setting.
3.
[Moving vertically], adjust the V.STAT magnet so that the
vertical red, green and blue dots coincide at the centre of the
screen.
vertical red, green and blue dots coincide at the centre of the
screen.
3-2. Convergence
By opening or closing the V.STAT magnet, the red green and blue
dots move in the direction indicated below.
dots move in the direction indicated below.
Note:
Do not adjust the H.STAT by rotating the V.STAT
magnets as this can affect the focus setting.
magnets as this can affect the focus setting.
B
G
R
B
G
R
Center dot
R
G
B
R
G
B
C Board
RV5375 (H STAT)
H STAT Convergence
(on mount side)
H STAT Convergence
(on mount side)
H STAT
convergence
control
V.STAT Vertical Static Magnet
Fig.3-5
Purity magnets
Align pips on
each magnet
each magnet
Fig.3-4
Align both Purity magnets
to the vertical position
to the vertical position
Purity control magnets
Purity control corrects
this area
this area
Disk magnets or
rotatable disk
magnets correct
these areas (a-d)
rotatable disk
magnets correct
these areas (a-d)
Deflection yoke positioning
corrects these areas
corrects these areas
a
c
d
b
Disk Magnets
Click on the first or last page to see other KV-34FQ75A service manuals if exist.