KV-32HS500 - Sony TV Service Manual (repair manual). Page 16

Read Sony KV-32HS500 Service Manual online

— 16 —
KV-32HS500/32HV600/34DRC500/34XBR800/36HS500/
36XBR800/38DRC500/40XBR800/42DRC800 
11.  LLMB (Left Lower Middle BOW)
B R
12.  CADJ Fix 29
2-4. FOCUS ADJUSTMENT
Confi rm neck assembly Z axis position. (See Figure 1)
1.  Input a dot signal.
2.  Set Video Mode to STANDARD.
3.  Adjust focus VR clockwise (DE-Focus) to confi rm that the dot’s shape 
is centered. (Figure 2 & 3) Confi rm neck assembly rotation by W Board 
position. W Board should be level ±1º. Adjust as necessary to balance 
dot shape along center horizontal line, then refocus.
4.  Input a HD monoscope signal.
5.  Confi rm center focus with focus VR.
Figure 1
FOCUS
Screen (G2)
DOT SHAPE:
NOTE: Changing neck assembly position will affect corner convergence.
2-4.1.  DYNAMIC FOCUS/DYNAMIC QUADRA-
POLE DATA
Normally, no adjustments are necessary for these systems. If for some 
reason the data is lost, use the following data:
Write the data from any non-vertically compressed mode, then use the 
CPY1 function (CXA2170D-4 Item 6) to copy the data to the vertical 
compressed modes. V-compressed data is identical to non-v-compressed 
data. Service personnel with a trained eye can adjust the 
DF or DQP registers to adjust DF phase (Item 7) or DQP 
phase (Item 8), respectively, to balance left and right focus. 
Refrain from adjusting more than 5 steps from table data below. 
Further adjustment indicates a circuit problem -- troubleshoot to 
cause. Be sure that Neck Assembly is in the proper location 
(See Section 2-4 Figure 1) before changing DF/DQP data or 
troubleshooting circuit when DF/DQP is suspect.
Figure 2
Figure 3