KV-29SE10B - Sony TV Service Manual (repair manual). Page 6

Read Sony KV-29SE10B Service Manual online

- 6 -
BX-1L SELF DIAGNOSTIC SOFTWARE
BX-1L chassis TV’s contain a self diagnosis function. In the event of an error occurring, the STANDBY LED indicator will automatically begin
to flash. The number of times the STANDBY LED indicator flashes translates to a probable source of the problem. If an error symptom cannot
be reproduced, the remote commander can be used to review the failure occurrence data stored in memory to reveal past problems and how often
these problems occur.
1. DIAGNOSTIC TEST INDICATORS
When an error occurs, the STANDBY indicator will flash a set number of times to indicate the possible cause of the problem. If there is more
than one error, the indicator will identify the first of the problem areas.
The result for all of the following diagnosis items are displayed on screen. No error has occured if the screen displays a “0”.
*
If a+B overcurrent is detected, then the vertical deflection is detected simultaneously. The symptom that is diagnosed first by the micro
controller is displayed on the screen.
**
Refer to Screen (G2) Adjustment on page 19.
2. DISPLAY OF STANDBY INDICATOR FLASH COUNT
V
Lamp OFF 3 sec 
Lamp ON 300ms
Lamp OFF 300ms
Diagnostic Item
Flash Count
+B Overcurrent
2 flashes
V-Protect
4 flashes
IK (AKB)
5 flashes
HV Protect
8 flashes
* One flash count is not used for self-diagnosis.
Diagnosis
Item
Description
Power does
not turn on
+B overcurrent
(OCP)*
V-Protect
IK (AKB)
HV Protect
No. of timer
STANDBY (
1)
indicator flashes
Does not light
2 times
4 times
5 times
8 times
Self-Diagnostic
display/
Diagnosis result
2:0
or
2:1 ~ 255
4:0
or
4:1 ~ 255
5:0
or
5:1 ~ 255
8:0
or
8:1 ~ 255
Probable Cause
Location
• Power cord is not plugged
in.
• Fuse is burned out (F4601)
A board.
• H OUT (Q511) is shorted.
(A board)
• IC751 is shorted. (C board)
• +13V is not supplied.
(A board)
• IC503 is faulty. (A board)
• Video OUT (IC751) is
faulty. (C board)
• IC001 is faulty. (A board)
• Screen (G2) is improperly
adjusted.**
• IC604 faulty.
• IC602 faulty.
Detected
Symptoms
• Power does not come on.
• No power is supplied on
TV.
• AC Power supply is faulty.
• Power does not come on.
• Load on power line is
shorted.
• Has entered standby state
after horizontal raster.
• Vertical deflection pulse is
stopped.
• Power line is shorted or
power supply is shorted.
• No raster is generated.
• CRT Cathode current
detection reference pulse
output is small.
• No power supply to CRT
ANODE.
• No RASTER is generated.
Page of 59