KV-29FS150 - Sony TV Service Manual (repair manual). Page 8

Read Sony KV-29FS150 Service Manual online

KV-29FS150
KV-29FS150 
8
3. Stopping the STANDBY LED Indicator Flash
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY LED Indicator from fl ashing.
4. Self-Diagnostic Screen Display
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confi rmed, it is possible to bring up past 
occurrences of failure on the screen for confi rmation.
To Bring Up Screen Test
In standby mode, press buttons on the Remote Commander sequentially, in rapid succession, as shown below:
 
DISPLAY
  
 Channel  5      
 Sound Volume  -  
 
 POWER
 
 
Note that this differs from entering the Service Mode (Sound Volume  +  ).
The following screen will be displayed indicating the error count:
 
SELF DIAGNOSTIC
2 OCP 
: 0
3 OVP 
N/A
4 VSTOP  : 
Number “0” means that no fault was detected.
5 AKB 
Number “1” means a fault was detected one time only.
8 SUP 
 
0
101 WDT 
 N/A
SERIAL:   FFFFFFF
MODEL: FFFFFFFF
Handling of Self-Diagnostic Screen Display
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen during repairs. When you 
have completed the repairs, clear the result display to “0”.
Unless the result display is cleared to “0”, the self-diagnostic function will not be able to detect subsequent faults after completion of the repairs.
Clearing the Result Display
To clear the result display to “0”, press buttons on the Remote Commander sequentially when the diagnostic screen is displayed, as shown below:
Channel  8  
  0
Quitting the Self-Diagnostic Screen
To quit the entire self-diagnostic screen, turn off the power switch on the Remote Commander or the main unit.