KV-29FA240 - Sony TV Service Manual (repair manual). Page 6

Read Sony KV-29FA240 Service Manual online

KV-29FA240
KV-29FA240 
7
SELF-DIAGNOSTIC FUNCTION
 
*One flash count is not used for self-diagnostic.
*If a +B overcurrent is detected, stoppage of the vertical deflection is detected simultaneously.  The symptom that is diagnosed first by the mircrocontroller 
is displayed on the screen.
**Refer to Screen (G2) Adjustments in Section 2-4. of this manual.
2. Display of STANDBY LED Flash Count
2 times
4 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
 
Standby indicator
Self Diagnosis
Supported model
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY LED indicator will automatically begin to flash. The number of 
times the LED flashes translates to a probable source of the problem. A definition of the STANDBY LED flash indicators is listed in the instruction manual 
for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review the failure occurrence 
data stored in memory to reveal past problems and how often these problems occur.
1. Diagnostic Test Indicators
When an error occurs, the STANDBY LED indicator will flash a set number of times to indicate the possible cause of the problem. If there is more than 
one error, the indicator will identify the first of the problem areas.
Results for all of the following diagnostic items are displayed on screen.  No error has occurred if the screen displays a “0”.
Diagnosis
Item
Description
• No Power
• +B overcurrent
(OCP)
• Vertical NG.
• IK (AKB)
• Supply Voltage
Protection
Detected
Symptoms
• Power does not turn on.
• No power is supplied to the
TV.
• AC power supply is faulty.
• Power does not turn on.
• Load on power line is
shorted.
• Has entered standby state
after horizontal raster.
• Vertical deflection pulse is
stopped.
• Power line is shorted or
power supply is stopped.
• No raster is generated.
• CRT cathode current
detection reference pulse
output is small.
• No power supply to CRT
ANODE.
• No RASTER is generated.
No. of times
STANDBY
Indicator flashes
Does not light
2 times
4 times
5 times
8 times
Diagnostic Result
on screen display
2 OCP:0
2 OCP:1 ~ 255
4 VSTOP:0
4 VSTOP:1 ~ 255
5 AKB:0
5 AKB:1 ~ 255
8 SUP:0
8 SUP:1 ~ 255
Probable
Cause
Location
• Power cord is not plugged
in.
• Fuse is burned out (F4101)
(H2 Board)
• H.OUT (Q511) is shorted.
(A board)
• IC751 is shorted.
(CV Board)
• +13V is not supplied.
(A Board)
• IC503 voltage list is faulty.
(A Board)
• Video OUT (IC751) is faulty.
(CV Board)
• IC001 is faulty. (A Board)
• Screen (G2) is improperly
adjusted.
• IC604 faulty.
• IC607 faulty.
Page of 63