KV-27V42 - Sony TV Service Manual (repair manual). Page 6

Read Sony KV-27V42 Service Manual online

— 6 —
KV-27V42/27V66/29SL42K/29SL42T/29VL42T/29XL42T
Handling of Self-diagnostic Screen Display
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen during
repairs. When you have completed the repairs, clear the result display to “0”.
Unless the result display is cleared to “0”, the self-diagnostic function will not be able to detect subsequent faults after completion
of the repairs.
Clearing the Result Display
To clear the result display to “0”, press buttons on the Remote Commander sequentially when the diagnostic screen is displayed,
as shown below:
ENTER
Channel 8
Quitting the Self-Diagnostic Screen
To quit the entire self-diagnostic screen, turn off the power switch on the Remote Commander or the main unit.
Self-diagnostic Circuit
IC301
Y/CHROMA JUNGLE
IC541
V. OUT
IC001
SYSTEM
IC003
MEMORY
IK IN
FROM
CRT
21
HP/PROTECT
SDA
FROM
IC521
PIN 7
18
35
IO-SDAT
O-LED
37
REF
3
I-PROT
IO-BDAT
17
36
B-DAT
5
18
DISPLAY
+B overcurrent (OCP)
Occurs when an overcurrent on the +B (115V) line is detected by pin 18 of IC301. If the voltage
of pin 18 of IC301 is less than 1V when V.SYNC is more than seven verticals in a period, the
unit will automatically turn off.
Vertical deflection stopped
Occurs when an absence of the vertical deflection pulse is detected by pin 17 of IC001. Power
supply will shut down when waveform interval exceeds 2 seconds.
White balance failure
If the RGB levels* do not balance within 2 seconds after the power is turned on, this error will be
detected by IC301. TV will stay on, but there will be no picture.
*(Refers to the RGB levels of the AKB detection Ref pulse that detects 1K.)