KV-27HS420/29DRC430/32HS420 ECG WIRE DRESSING
DY
Rotation
COIL
COIL
g
Rev. 1
3/11/05
3/11/05
CRT BRKT
Earth Coating
Ground Wire (ECG)
32”: 1-900-808-29
Ground Wire (ECG)
32”: 1-900-808-29
(Earth Coating Ground)
Integral Spring
2-Places
2-Places
NOTE: Leads are
dressed inside
Rotation Coil.
dressed inside
Rotation Coil.
NOTE2: There are
2 Leads (TOTAL 4
Wires) to connect
to CH-Board
2 Leads (TOTAL 4
Wires) to connect
to CH-Board
Caution Points:
1. Make sure braided ECG wire loop does not
twist, and stays flat on CRT surface.
twist, and stays flat on CRT surface.
2. Do not pull excessively on the tension spring
3. If the spring appears warped or stretched,
replace entire parts. The braided ECG wire
CANNOT sag on the CRT, and must remain
under tension.
replace entire parts. The braided ECG wire
CANNOT sag on the CRT, and must remain
under tension.