KV-27FS100 - Sony TV Service Manual (repair manual). Page 6

Read Sony KV-27FS100 Service Manual online

— 7 —
KV-27FS100/27FS200/29FS100/
32FS100/32FS200/34FS100
SELF-DIAGNOSTIC FUNCTION
Display of Standby/Timer LED Flash Count
3 times
2 times
4 times
5 times
9 times
10 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
 
Diagnostic Item   
Flash Count*
 
+B Overcurrent 
 
2 times
 
+B Overvoltage 
 
3 times
 
V-STOP   
 
4 times
 
IK (AKB)   
 
5 times
 
Zero Cross 
 
9 times
 
9V  
 
 
10 times
*One fl ash count is not used for self-diagnostic.
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to fl ash. The number 
of times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY/TIMER LED fl ash indicators is listed in the 
instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review 
the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will fl ash a set number of times to indicate the possible cause of the problem. If there is more than 
one error, the LED will identify the fi rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. If the screen displays a “0”, an error has occurred.
Self Diagnosis
Supported model
Standby/Timer LED
Diagnostic Item
No. of times
STANDBY / TIMER
lamp flashes
Probable Cause Location
Detected Symptoms
Power does not turn on
Does not light
Power cord is not plugged in.
Fuse is burned out (F601). (GK Board)
Power does not come on.
No power is supplied to the TV.
AC Power supply is faulty.
+B overcurrent (OCP)*
2 times
H.OUT (Q502) is shorted. (A Board)
IC702 is shorted. (C Board)
Power does not come on.
Load on power line shorted.
+B overvoltage (OVP)
3 times
IC501 is faulty. (A Board)
If a high is supplied to pin 2 of IC501.
(A Board)
Has entered standby mode.
I-Prot
4 times
+12V is not supplied. (A Board)
IC561 is faulty. (A Board)
Has entered standby state after
horizontal raster.
Vertical deflection pulse is stopped.
Power line is shorted or power
supply is stopped.
IK (AKB)
5 times
Video OUT (IC561) is faulty. (A Board)
IC702 is faulty. (C Board)
Screen (G2) is improperly adjusted. **
No raster is generated.
CRT Cathode current detection
reference pulse output is small.
Zero Cross
9 times
No zero cross pulses on pin 45
IC1001. (A Board)
Power does not come on.
9V Check
10 times
Relay failed (RY600)
Power does not come on.
* Ifa +B overcurrent is detected, stoppage ofthe vertical deflection is detected simultaneously. The symptom that is diagnosed first
by the microcontroller is displayed on the screen.
** Refer to Screen (G2) Adjustments in Section 2-4 of this manual
Page of 127