KV-27FA310 - Sony TV Service Manual (repair manual). Page 13

Read Sony KV-27FA310 Service Manual online

14
KV-27FA310/27FS120/29FA310/29FS120
KV-27FA310/27FS120/29FA310/29FS120
2-2. CONVERGENCE
Before starting convergence adjustments:
1  Perform FOCUS, VLIN and VSIZE adjustments.
2.  Set BRIGHTNESS control to minimum.
3.  Feed in dot pattern.
Vertical Static Convergence
1.  Adjust V. STAT magnet to converge red, green and blue dots in the 
center of the screen. 
2.  Tilt the V. STAT magnet and adjust static convergence to open or 
close the V. STAT magnet.
 
When the V. STAT magnet is moved in the direction of arrow a and b, 
red, green, and blue dots move as shown below:
B
R
G
B
R
G
R
G B
B
G R
1
2
b
b
b
b
b
b
b
a
a
b
a
a
a
a
3
R
G
B
B
G
R
Horizontal Static Convergence
If the blue dot does not converge with the red and green dots, perform 
the following:
1.  Move H STAT VR magnet (a) to correct insuffi cient H.Static 
convergence.
BMC MA
GNET
PURITY
V.STAT
H STAT VR
B
G
R
Center dot
V.STAT magnet
RV2750
H.STAT
B
G
R
Page of 79