KV-25B5E - Sony TV Service Manual (repair manual). Page 4

Read Sony KV-25B5E Service Manual online

4
StBy LED
ON
ON
ON
OFF
OFF
(ON SCREEN
   DISPLAY)
5
(DIGIT 5)
(VOLUME -)
(TV)
i
+
Table 1
Flash Timing Example : e.g. error number 3
How to enter into Table 2
1.
Turn on the main power switch of the TV set and enter into the 
‘Standby Mode’.
2.
Press the following sequence of buttons on the Remote 
Commander.
3.
The following table will be displayed indicating the error 
count.
Table 2
Note: To clear the error count data press ‘80’ on the Remote 
commander.
ERROR
LED
ERROR
COUNT
 No error
00
Not allowed (may be confused with Sircs response 
flash!)
01
Protection circuit trip < ANY TIME >
02
Reserved
03
No vertical sync
04
AKB
05
IIC bus clock and/or data lines low at Power ON
06
NVM no IIC bus acknowledge at Power ON
07
Jungle controller no IIC acknowledge at Power ON
08
Tuner no acknowledge at Power ON
09
Sound processor no acknowledge at Power ON
10
Error                                                    Times
  2                                                              -
  3                                                              -
  4                                                              -
  5                                                              -
  6                                                              -
  7                                                              -
  8                                                              -
  9                                                              -
 10                                                             -
FE-1 SELF DIAGNOSTIC SOFTWARE
The identification of errors within the FE-1 chassis is triggered in one of two ways :- 1: Busy  or 2: Device failure to respond to IIC. In the event 
of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with continuous flashing LED) and 
then communicate with each device in turn to establish if a device is faulty. If a device is found to be faulty the relevant device number will be dis-
played through the LED (Series of flashes which must be counted) See Table 1., non fatal errors are reported using this method.
Each time the software detects an error it is stored within the NVM. See Table 2.