KV-21XE42C - Sony TV Service Manual (repair manual). Page 21

Read Sony KV-21XE42C Service Manual online

— 21 —
KV-21XE42C
A
 BOARD
 R582 CONFIRMATION METHOD 
 
(HV HOLD-
DOWN CONFIRMATION)  AND READJUSTMENTS
The following adjustments should always be performed when
replacing the following components which are marked with 
] on
the schematic diagram:
IC301, IC521, IC602, D572, D573, D574, DY,
C511, C574, C575, R578, R582, R583, R584,
R585, R586,R625, R626, R634, R635, T504 (FBT)
(1)  Preparation before Confirmation
 1) Turn the POWER switch ON. Input an entirely white
signal and set the PICTURE and BRIGHT controls to
maximum.
2) Confirm that the voltage between C574(+) and ground is
more than: 99.8VDC
when the set is operating normally with 120.0-240.0 
±
 2.0
VAC.
(2) Hold-down Operation Confirmation
1) Connect the current meter between Pin 11 of the FBT
(T504) and the PCB land where Pin 
11
 would normally attach.
  2) Input a dot signal and set PICTURE and BRIGHTNESS to
minimum:
IABL = 95+100/-95
µ
A
3) Confirm the voltage of A board TP-600  is
116.8 
±
 0.3VDC
4) Connect the Digital Voltmeter and the DC power supply
via diode 1SS119 to C574 (+).  (See figure 1.0 on next page.)
5) Increase the DC power voltage gradually until the picture blanks out.
6) Read the digital voltmeter indication.
7) Turn DC power source off immediately.
STANDARD
Less than or equal to: 127.3 VDC
8) Input a white signal and set PICTURE and BRIGHTNESS to Max
9) Repeat steps from (4) to (7).
STANDARD
Less than or equal to: 127.3 VDC
SECTION 4
SAFETY RELATED ADJUSTMENTS
The following adjustments should always be performed
           when replacing the following components which are marked
           with 
] on the schematic diagram:.
IC001, IC602, R030, R626, R632,
R633, R635, R636, R637, R638, R639
   1) Supply 130 
±
 
2.0
0
  VAC  to the set with a variable auto
transformer.
2) Input a dot signal.
3) Set the PICTURE control and the BRIGHT control to
minimum condition.
4) Set to service adjustment mode.
5) Select PADJ with 
 and 
 .
6) Adjust with   to the 0 level.
7) Confirm the voltage of A BOARD TP-600 is less than
125V DC.
8) If step 7 is not satisfied, replace the components, repeat the
above steps.
9) Supply 120.0 
±
 2.0 VAC to the set with a variable auto
transformer.
10) Adjust with 
 and 
 for: 116.8 
±
 0.3V DC
11) Write into the memory by pressing 
 then 
.
 
B+ VOLTAGE CONFIRMATION AND ADJUSTMENT
(3) Hold-down Readjustment
If the current setting indicated in step 2-2 cannot be met,
readjustment should be performed by altering the resistance
value of R582, a component marked with 
.
+
I  ABL
ABL
T504
FBT
range
-
ammeter
3.0 mA DC
A
Page of 41
Display

Click on the first or last page to see other KV-21XE42C service manuals if exist.