KV-21FS105 (serv.man2) - Sony TV Service Manual (repair manual). Page 6

Read Sony KV-21FS105 (serv.man2) Service Manual online

7
KV-21FS105
KV-21FS105
SELF-DIAGNOSTIC FUNCTION
Display of Standby/Timer LED Flash Count
2 times
4 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
 
Diagnostic Item 
 
Flash Count*
 
+B Overcurrent 
 
2 times
 V-STOP 
  4 
times
 
White Balance Failure 
5 times
*One fl ash count is not used for self-diagnostic.
Stopping the Standby/Timer LED Flash
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER LAMP from fl ashing.
Self-Diagnostic Screen Display
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confi rmed, it is possible to bring up past 
occurrences of failure on the screen for confi rmation.
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to fl ash. The number of 
times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY/TIMER LED fl ash indicators is listed in the instruction 
manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review the failure 
occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will fl ash a set number of times to indicate the possible cause of the problem. If there is more than one 
error, the LED will identify the fi rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. If the screen displays a “0”, an error has occurred.
Diagnostic Item
Description
No. of Times
STANDBY/TIMER
LED Flashes
Self-Diagnostic Display/
Diagnostic Result
Probable Cause
Location
Detected Symptoms
Power does not turn on
Does not light
• Power cord is not plugged in.
• Fuse is burned out. (F601) (A Board)
• Power does not come on.
• No power is supplied to the TV.
• AC power supply is faulty.
+B overcurrent (OCP)*
times
2:0 or 2:1
• H.OUT (Q502) is shorted. (A Board)
• IC702 is shorted. (CB Board)
• Power does not come on.
• Load on power line is shorted.
Vertical deflection stopped*
times
4:0 or 4:1
• +12V is not supplied. (A Board)
• IC502 is faulty. (A Board)
• Has entered standby state after horizontal raster.
• Vertical deflection pulse is stopped.
• Power line is shorted or power supply is stopped.
White balance failure
(not balanced)
5 times
:0 or 5:1
• Video OUT (IC502) is faulty. (A Board)
• IC1301 is faulty. (MB Board)
• Screen (G2) is improperly adjusted.**
• No raster is generated.
• CRT cathode current detection reference
pulse output is small.
2
4
5
 
*   If a +B overcurrent is detected stoppage of the vertical defl ection is detected simultaneously.
 
    The symptom that is diagnosed fi rst by the microcontroller is displayed on the screen.
 
**  Refer to Screen (G2) Adjustments in Section 2-4. of this manual.
Self Diagnosis
Supported model
Standby/Timer LED
Page of 48
Display

Click on the first or last page to see other KV-21FS105 (serv.man2) service manuals if exist.