— 15 —
KV-20FS100/20FV300/21FM100/21FS100/
21FV300/24FV300/25FV300
HOLD-DOWN READJUSTMENT
If the setting indicated in Step 2 of Hold-Down Operation Confi rmation 
cannot be met, readjustment should be performed by altering the 
resistance value of R565 component marked with X. 
+
IABL
ABL
T585
FBT
range
-
amPmeter
3.0 mA  DC
A
3-2. B+ VOLTAGE CONFIRMATION AND 
ADJUSTMENT
Note: The following adjustments should always be performed when 
replacing the following components, which are marked with Y on the 
schematic diagram on the A Board:
   A BOARD: 
IC600, PH602
1.  Using a Variac, apply AC input voltage: 130 + 2.0 / - 0.0 VAC.
2.  Input a DOT pattern at Q.C.
3.  Set the PICTURE  and the BRIGHTNESS controls to minimum.
4.  Confi rm the voltage of A Board between TP-23 & Ground is <135.6 
± 1 VDC.
5.  If step 4 is not satisfi ed, replace the components listed above, then 
repeat Steps 1 – 3.   
               
SECTION 3:  SAFETY RELATED ADJUSTMENTS
3-1. X R565 CONFIRMATION METHOD  
(HV HOLD-DOWN CONFIRMATION) AND 
READJUSTMENTS
The following adjustments should always be performed when 
replacing the following components which are marked with Y on the 
schematic diagram:
Part Replaced (   )
Adjustment (   )
DY, T585, CRT, IC001, IC561, 
C507, C508, C506, T511, L510, 
C588, L588, C566, C561, C563, 
D567, D568, D566, R567, R568, 
R565, R566, R562, R563, R561, 
R528....................A Board
HV HOLD-DOWN
R565
PREPARATION BEFORE CONFIRMATION
1.  Using a Variac, apply AC input voltage: 120 ±2 VAC.
2.  Turn the POWER switch ON.
3.  Input a white signal and set the PICTURE and BRIGHTNESS 
controls to maximum.
4.  Confi rm that the voltage between C566 (+) or TP30 and ground is 
more than 97.0 VDC for 20” and 105 VDC for 24”. 
 
HOLD-DOWN OPERATION CONFIRMATION
1.  Connect the current meter between Pin 11 of the FBT (T585) and 
the PWB land where Pin 11 would normally attach (See Figure 1 
on the next page).
2.  Input a dot signal and set PICTURE and BRIGHTNESS to 
minimum: IABL = 100 ± 100µA.
3.  Confi rm the voltage of A Board TP-23 is 135.6 ± 1V.
4.  Connect the digital voltmeter and the DC power supply via Diode 
1SS119 to C566 (+) and ground (See Figure 1 on next page).
5.  Increase the DC power voltage gradually until the picture blanks 
out.
6.  Turn DC power source off immediately.
7.  Read the digital voltmeter indication (standard < 117VDC).
8.  Input a white signal and set PICTURE and BRIGHTNESS to 
maximum: IABL = 1350 ± 100µA.
9.  Repeat steps 4 to 7.