6. Self-diagnosis function operation
OCP
Low B and +B line detect DET SHORT, and shut-down POWER ON RELAY.
Reset by turning power on/off.
In case of +B is loaded approx. 1.5A or more, microcomputer detects it via IC6102.
OVP
In case of +B becomes approx. 150V or more, POWER ON RELAY shuts down and microcomputer detects it via IC6102.
Reset by turning power on/off just the same as OCP.
V Stop
In case of V Drive disappeared, Q5005 detecs it and shut-down POWER ON RELAY. Microcomputer detects it and makes LED
blinking.
AKB
IK detection.  Makes LED blinking in case of microcomputer doesn’t detect IK returns of IC511  (CXA2101AQ) 30 seconds or
more.
H Stop
In case of H DRIVE is disappeared, Q5006 detects it and shut-down POWER ON RELAY shuts down.
Microcomputer receives H Stop data from Q5006 and makes LED blinking.
HV Stop In case of HV becomes 33KV or more. IC8006 and IC8010 detect it and shut-down
POWER ON RELAY. Microcomputer makes LED blinking.
Audio
In case of DC component overlaps the output of Audio Amp., POWER ON RELAY shuts down.
Microcomputer detects it and makes LED blinking.
Self-diagnosis block diagram
53
48
50
3
4
5
6
7
13
49
47
50
55
27
28
33
5. AKB
5. AKB
3. OVP
2. OCP
4. V.STOP (V Pulse)
6. H.STOP
7. HV.STOP
8. Audio
2. OVP
3. OCP
4. V.STOP
6. H.STOP
7. HV STOP
8. AUDIO
IC1008
MAIN-CPU
IC1009
OSD-CPU
IC511
CXA2101AQ
MCP
D3102
TIMER/STANDBY
R1802
IC1007
EEPROM
Q5006
H PULSE
Detector
IC8006,8010
HV Detector
IC512
CXD2018Q
VDSP
Q5005
V Pulse Detector
IC6102
 OVP Buffer
OCP Buffer
C Board
DC Detect
IC5004
V Drive
IC2002
6. H STOP
BUS
BUS
56
48
OVP DETECT
OCP DETECT
16
22
Audio AMP