— 9 —
KP-57WV600
Self-Diagnosis Function Operation
+B overcurrent (OCP) 
Occurs when excessive current flows through R5013. The increase in voltage across R5013 causes the output of Q5004 to go high, and this high 
signal goes to the micro. 
+B overvoltage (OVP) 
IC6505 detects +B OVP condition and turns on Q6522. This sends a high signal to the micro and also shuts down the AC relay.
V-STOP 
Occurs when an absence of the vertical deflection pulse is detected by pin 24 of IC2801 (B Board). Power supply will shut down when waveform 
interval exceeds 2 seconds. 
White Balance Failure
If the RGB levels* do not balance within 2 seconds after the power is turned on, this error will be detected by IC2801. TV will stay on, but there will be 
no picture.
*(Refers to the RGB levels of the AKB detection Ref pulse that detects 1K).
Low B OCP/OVP
Occurs when set 5V is out.
Horizontal Deflection Stopped
Occurs when either: 
 
1) a +B overcurrent is detected (IC5007), or 
 
2) overheating is detected (Thermistor TH5002).
Self-Diagnosis Block Diagram
1
2
4
3
3
1
2
R5104
R5105
R5125
Q5018
RY6501
Q6527
Q6530
Q6532
D6537
D6505
D5007
PH6501
Q5004
R5013
D5005
IC6505
Q6522
1K-PROT2
+B OVP
HV PROT
UNREG 11V
5V
UNREG 7V
+B OCP
2
1
3
4
IC5007
VDY-
CRT
IC2801
Y/C JUNGLE
SCL
SDA
AKB
VPROT
HPROT
IC2300
MAIN MICRO
MB
CLKO
DATO
AC RLY
LOW B ERR
OVP
OCP
STR
STBY-LED
STBY-LED
P_SW(-)
IC504
5V
+B
+B
+B
D
B
MB
D
D
A
2
14
34
35
58
26
25
29
30
69
43
44
45
48
O
I
O
Page of 127
Display

Click on the first or last page to see other KP-57WV600 (serv.man2) service manuals if exist.