KP-51WS500, KP-57WS500, KP-65WS500 - Sony TV Service Manual (repair manual). Page 7

Read Sony KP-51WS500 / KP-57WS500 / KP-65WS500 Service Manual online

— 8 —
KP-51WS500/57WS500/65WS500
Display of Standby/Timer LED Flash Count
Lamp OFF : 
3.0 seconds
Lamp ON : 0.3 seconds
Lamp OFF : 0.3 seconds
*  One blink is not used for self-diagnosis.
EXAMPLE
<Diagnosis Items>  <Number of Blinks>
 +B overcurrent  
2 times
 +B overvoltage
3 times
 Vertical deflection stop
4 times
< FRONT PANEL >
TIMER/STAND BY indicator
Release of TIMER STAND BY indicator blinking
The TIMER/STANDBY indicator blinking display is released by turning OFF the power switch on the TV main unit or removing the plug from the 
power.
Self-Diagnosis Screen Displays
In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when the screen 
disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether the detection circuit operated 
or not) in order to allow confi rmation.
      
Screen Display Method
Quickly press the remote command button in the following order from the standby state.
  Display  
  Channel  5   
  Sound Volume* 
_
  
  Power ON 
 
 
 
 
 
*Note that this differs from entering the service mode (sound volume  +  )
SELF DIAGNOSIS
    2 : +B  OCP
N/A
    3 : +B  OVP
N/A
    4 : V STOP
0
    5 : AKB
1
    10 : WDT
24
Numeral "0" means that no fault
was detected.
Numeral "1" means a fault was detected
one time or more
Self-Diagnosis Screen Display
The results display is not automatically cleared.  In case of repairs and after repairs, check the self-diagnosis screen and be sure to return the 
results display to “ 0 ”. 
If the results display is not returned to “ 0 ” it will not be possible to judge a new malfunction after completing repairs.
Method of Clearing Results Display
1.  Power off (Set to the standby mode.)
2.   Display  
  Channel  5   
  Sound Volume  +   
  Power ON (Service Mode) 
3.  Channel  8   
   ENTER  (Test reset = Factory preset condition)
Method of Ending Self Diagnosis Screen
When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main unit.