KP-51HW40, KP-57HW40 - Sony TV Service Manual (repair manual). Page 6

Read Sony KP-51HW40 / KP-57HW40 Service Manual online

– 6 –
KP-51HW40/57HW40
RM-Y909
RM-Y909
4.
Self-diagnosis screen displays
In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when
the screen disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether
the detection circuit operated or not) in order to allow confirmation.
<Screen Display Method>
Quickly press the remote command button in the following order from the standby state.
5.
Self-Diagnosis Screen Display
The results display is not automatically cleared.  In case of repairs and after repairs, check the self-diagnosis screen and be sure
to return the results display to “ 0 ”.
If the results display is not returned to “ 0 ” it will not be possible to judge a new malfunction after completing repairs.
<Method of Clearing Results Display>
<Method of Ending Self Diagnosis Screen>
When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main unit.
   
˘
   Be aware that this differs from the method of 
   entering the service mode (volume   +   ).
DISPLAY   
b   Channel    5   b   VOL    –    b   POWER
SELF DIAGNOSIS
    2 : +B  OCP
N/A
    3 : +B  OVP
N/A
    4 : V STOP
0
    5 : AKB
1
    10 : WDT
24
Numeral “0” means that no fault
was detected.
Numeral “1” means a fault was detected
one time or more
Self-diagnosis screen display
1. Power off (Set to the standby mode)
2. DISPLAY   
b   Channel    5    b   VOL    +    b    POWER    (Service Mode)  
3. Channel    8   
b   ENTER   (Test reset = Factory preset condition)