KP-48PS2, KP-61PS2 - Sony TV Service Manual (repair manual). Page 5

Read Sony KP-48PS2 / KP-61PS2 Service Manual online

– 5 –
KP-48PS2/61PS2
K
RM-903
SECTION  1
SELF  DIAGNOSIS  FUNCTION
1-1. RE-3 SELF DIAGNOSTIC SOFTWARE
The identification of errors within the RE-3 chassis is triggered in one of two ways : - 1: Busy or 2: Device failure to respond to IIC. In
the event of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with
continuous flashing LED) and then communicate with each device in turn to establish if a device is faulty. If a device is found to be
faulty the relevant device number will be displayed through the LED (Series of flashes which must be counted) See table 1., non fatal
errors are reported using this method.
Power cord is not plugged in
Power does not come on
Power does not turn on
Does not light
Fuse is Burned out
No power is supplied to the TV
AC power supply is faulty
H. OUT (Q5104) is shorted (D Board)
Power does not come on
+B Over current (OCP)
2 times
Linearity FET (Q5105) is shorted (D Board)
IC6004 Power IC is shorted (G Board)
Load on power line has shorted
+15 V is not supplied R5340 open (D Board)
Vertical deflection pulse has stopped
Vertical Deflection stopped
4 times
–15 V is not supplied R5341 open (D Board)
Power line has shorted
IC5302 is shorted (D Board)
No. of times Standby
LED Flashes
Detected Symptoms
LED
ERROR
ERROR
COUNT
No error
00
Not allowed (may be confused with Sircs response flash)
01
Over Current Protection
02
Over Voltage Protection
03
Vertical Protection
04
Not used
05
H-Protection
06
Speaker Protection
07
General IIC Line 0 error
08
MEGATEXT (IC9502)
09
NVM (IC9108)
10
Main colour decoder (IC8301)
11
Backend (IC4301)
14
Multi sound processor (IC4702)
15
External RAM (IC9107)
17
Diagnostic Item
Description
Probable cause Location
Flash Timing Example : e.g. error number 3
ON
OFF
OFF
ON
ON
Standby LED
Page of 127
Display

Click on the first or last page to see other KP-48PS2 / KP-61PS2 service manuals if exist.