KP-46WT520, KP-51WS520, KP-57WS520 (serv.man2) - Sony TV Service Manual (repair manual). Page 6

Read Sony KP-46WT520 / KP-51WS520 / KP-57WS520 (serv.man2) Service Manual online

KP-46WT520/51WS520/57WS520
KP-46WT520/51WS520/57WS520 
7
SELF-DIAGNOSTIC FUNCTION
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to fl ash. The number 
of times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY/TIMER LED fl ash indicators is listed in the 
instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review 
the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will fl ash a set number of times to indicate the possible cause of the problem. If there is more than 
one error, the LED will identify the fi rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. If the screen displays a “0”, no error has occurred.
Diagnostic Item 
No. of times 
STANDBY / 
TIMER  lamp 
flashes 
Display 
Result 
Probable Cause Location 
Detected Symptoms 
Power does not turn on  
Does not light 
_______ 
  Power cord is not plugged in. 
Fuse is burned out (F6000). (G Board)
  Power does not come on. 
  No power is supplied to the TV. 
  AC Power supply is faulty. 
+B Overcurrent (OCP)* 
2 times 
2:0 or 2:1 
  H.OUT (Q5001) is shorted. (D Board) 
  +B PWM (Q5201) is shorted.  
(D Board) 
  Power does not come on. 
  Load on power line shorted. 
+B Overvoltage (OVP)
3 times
3:0 or 3:1
IC6503 is faulty. (D Board)
Has entered standby mode.
Vertical Deflection Stopped 
4 times 
4:0 or 4:1 
  15V is not supplied. (D Board) 
  IC5101 is faulty. (D Board) 
  Has entered standby mode after 
Horizontal raster. 
  Vertical deflection pulse is stopped. 
  Power line is shorted or power 
supply is stopped. 
White Balance Failure 
(not balanced) 
5 times 
5:0 or 5:1 
  Video OUT (IC9101, IC9201, IC9301) 
is faulty. (CR, CG, CB Board) 
CRT drive (IC452) is faulty.
(A Board)
  G2 is improperly adjusted.** 
  No raster is generated. 
  CRT cathode current detection 
reference pulse output is small. 
LOW +B OCP/OVP 
(overcurrent/overvoltage)*** 
6 times 
6:0 or 6:1 
  +5 line is overloaded.  
(A and BM Boards)
+5 line is shorted. (A and BM Boards)
IC303 is faulty. (A Board)
 No picture 
Horizontal Deflection 
Stopped 
7 times 
7:0 or 7:1 
  Q5006 is broken (D Board) 
IC452 is faulty (A Board)
 No picture 
Audio Protection 
8 times 
8:0 or 8:1 
  + or - 22V audio supply is not 
present—Check PS600  & PS601
Audio AMP is damaged IC601 on
A Board 
 No picture 
Zero Crossing Detector
9 times
9:0 or 9:1
D6116 or D6301 is open (G Board)
No picture
HV Protection 
10 times 
10:0 or 
10:1 
  Q8014 or Q8013 have shorted replace 
along with R8051 on D Board 
  IC8005 is damaged (D Board) 
 No picture 
*  If a +B overcurrent is detected, stoppage of the vertical deflection is detected simultaneously. The symptom that is diagnosed first by the 
microcontroller is displayed on the screen. 
** Refer to Screen (G2) Adjustment (Fine Adjustments) in Section 2 of this manual. 
*** If STANDBY/STEREO LED flashes six (6) times, unplug the unit and wait 10 seconds before performing the adjustment. 
Self Diagnosis
Supported model
Page of 127
Display

Click on the first or last page to see other KP-46WT520 / KP-51WS520 / KP-57WS520 (serv.man2) service manuals if exist.